IT
17
7539 Tab Free
1
2
3
4
beep
> 6s
beep
BEEP
BEEP
Configuration procedure ("Standard” Mode)
:
• Press and hold down the
key.
• Press the
key too and hold them down until the
key starts flashing.
• Release the keys.
• Press the
key within 5s of releasing the keys and keep it pressed until you hear a warning tone on the indoor station and the
communication is activated between the indoor station and the external electronic unit. If more than 5s passes without the
key being pressed, steps 1, 2 and 3 must be repeated.
• Release the
key.
• With a timeout of 25s associate the ID code from the external electronic unit, pressing the key of the outdoor station from which
you wish to receive the call (MASTER). (*)
•
The ID code is associated with the indoor station and communication is ended. An acoustic signal confirms the operation was
successful. (**)
ID code configuration
The identification code is programmed by means of a main entrance panel (MASTER), already configured and present in the
system. The indoor station is supplied without an associated identification code. To verify this condition, press the lock release key
and the indoor station should emit a triple “Beep".
Caution: when configuring the indoor station identification code, you only have 30 seconds from the moment you enter
indoor station configuration mode in which to press the call button on the outdoor station or to send the code.
Configuration procedure ("Simplified” Mode)
:
1. Press and hold down the lock release key “
” for 6 s. When the time runs out the indoor station will emit a “beep” (0.5 s).
3. Release the lock release key “
”. When the key is released the communication will be signalled by a “beep” with a different
frequency.
3. Press the key on the MASTER outdoor station you wish to receive the call from. (*)
4. The ID code is associated with the indoor station and communication is ended. An acoustic signal confirms the operation was
successful. (**)
N.B. (*): This procedure applies to entrance panels with push buttons; for alphanumerical entrance panels, type in the ID
code and confirm with the call key.
N.B. (**): If the system contains an indoor station that already has the same associated identification code (ID), the
entrance panel emits a lower tone and the operation will have to be repeated.