background image

IT

13

7539  Tab Free

This function is used to send a notice to the Reception Switchboard art 40510 even if the Due Fili Plus bus is busy.

To activate this function, you need to connect a push button to terminals FP-M and use the SaveProg software to set the operating 

mode (see 

Alert configuration via SaveProg

).

Now the video entryphone goes in stand-by and receives various answers depending on the actions of the Reception switchboard.

These answers may be visual or acoustic depending on the configuration set via SaveProg (see 

Alert configuration via 

SaveProg

).

Alert Function

1.  Press the push button to send an alert notification

FP
M

1

Содержание ELVOX Videocitofonia 7539

Страница 1: ...Tab 7539 Tab Free hands free Due Fili Plus video entryphone User Manual ...

Страница 2: ...IT 2 7539 Tab Free ...

Страница 3: ...unit volume adjustment 10 levels with indoor station in a conversation 14 Internal call voice unit volume adjustment 10 levels with indoor station in a conversation 14 Ringtone mute 14 Choice of call melodies 15 Configurations 16 First power up 16 ID code configuration 17 Secondary ID code configuration 18 Key configuration to make intercom calls 19 Configuration of a key for self start of a speci...

Страница 4: ...General information Warnings and advice The video entryphone can be used by people wearing hearing aids For correct functioning of the hearing aid please refer to its instruction manual Any metal objects or electronic equipment in the vicinity may affect the quality of the sound received by the hearing aid Tab Free hands free video entryphone with 3 5 colour display for Due Fili Plus systems It ha...

Страница 5: ... Station D Auxiliary 1 It activates the first relay of the Due Fili Plus system Aux 1 stair lights function F Talk listen G Volume control contrast H Brightness Control 1 1 Auxiliary 2 It activates the second relay Aux 2 of the Due Fili Plus system 2 2 Free 3 3 It sends an F1 control to Outdoor Stations 4 4 It sends an F2 control to Outdoor Stations the functions associated with the keys 1 2 3 4 c...

Страница 6: ...onds user away 1 flash every second the Indoor Station will refuse calls from an Outdoor Station Steady light communication under way Flashing during the timeout for sending a call to the reception switchboard Steady light if an opening has been left open when the specific connection has been made by the installer Flashing when a configuration is under way Possible Alert signalling see Alert funct...

Страница 7: ...phs refer to audio video calls from Outdoor Stations In the case of audio only Outdoor Stations the display will be black In the case of a video door entry call with no video signal the display will be blue For the operation of the video entryphone the ID identification must be configured To check whether an ID has been allocated to the video entryphone proceed as follows Functions ID assigned ID ...

Страница 8: ...he conversation press the key again Press the key to release the lock of the Outdoor Station connected the lock release is also available in stand by N B If it is not configured the indoor station in stand by opens the lock for the last calling outdoor station N B The activation of other actuators is also possible among those which can be programmed using keys Lock release ...

Страница 9: ...AM or Video selector for 4 cameras 69AM T If there is no answer to one or more calls from the Reception switchboard the LED flashes if the function was enabled from SaveProg The LED stops flashing after the Indoor Station has answered and returned to stand by or after the ringtone has been reactivated after a self start making any intercom call N B the missed call signal remains also in the case o...

Страница 10: ... progress a busy tone will be heard at the indoor station making the call To self start to the master entrance panel briefly press the key If the master entrance panel is audio press the key and press the key while it flashes 5 seconds You can also perform the self start of a specific Outdoor Station by using keys following appropriate configuration see Configuration of a key for self starting a s...

Страница 11: ... indoor station emits a tone in order to signal that the call is being made If the indoor station is already engaged with another call a tone will be heard on the indoor station making the call to indicate that the user receiving the call is busy When the called party answers the communication is automatically activated To end the conversation press the key The maximum length of an intercom conver...

Страница 12: ...out of 5s send the call by pressing the key During the timeout the key flashes 1 2 Landing call You can receive the call from a Landing button if connected to the FP M terminals of the indoor station The duration of the ringtone cycle depends on how long the key is pressed for a maximum time of 10s FP M 1 1 Press the push button to send a landing call ...

Страница 13: ...nd use the SaveProg software to set the operating mode see Alert configuration via SaveProg Now the video entryphone goes in stand by and receives various answers depending on the actions of the Reception switchboard These answers may be visual or acoustic depending on the configuration set via SaveProg see Alert configuration via SaveProg Alert Function 1 Press the push button to send an alert no...

Страница 14: ...ght hand side to adjust the brightness Contrast adjustment volume key Adjustment is possible during self starting without activating the voice unit Press the or key on the left hand side to adjust the contrast External call voice unit volume adjustment 10 levels with indoor station in a conversation Use the and keys on the left hand side to adjust the desired level It is adjusted during the conver...

Страница 15: ...ody Key 3 is used to select the LANDING CALL melody with specific electronic module 1 Press and hold down the key for 2 s until the key starts flashing accompanied by an audible warning 2 Press key 1 or 2 or 3 the indoor station will start playing the last melody in memory 3 Repeatedly press key 1 or 2 or 3 to select the kind of melody you want 4 Press the key to save the melody or wait 15s At the...

Страница 16: ...tion installation must be carried out by qualified persons in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed The indoor stations after being installed must be configured by assigning the ID code The ID code is unique for each appliance All CONFIGURATION operations must be performed with the system switched ...

Страница 17: ...ut an associated identification code To verify this condition press the lock release key and the indoor station should emit a triple Beep Caution when configuring the indoor station identification code you only have 30 seconds from the moment you enter indoor station configuration mode in which to press the call button on the outdoor station or to send the code Configuration procedure Simplified M...

Страница 18: ...ssociated with the same group The master indoor station is programmed first by means of the identification code configuration procedure described above while the additional group indoor stations are programmed with the secondary identification code The number of indoor stations that can be associated with the same group without using a SaveProg software is 3 plus a master station Configuration pro...

Страница 19: ...m on the calling indoor station Press a key on the indoor station to call F1 F2 An audible warning on the calling indoor station confirms that the procedure has been correctly completed key configuration to make intercom calls Configuration procedure Simplified Mode 1 Press the key to be programmed and hold it down for at least 6 s 2 When the indoor station has emitted a beep release the key being...

Страница 20: ...key At the end of the procedure described above the indoor station emits a signal to confirm that the operation has been successful and it is called by the outdoor station Configuration of a key for self start of a specific outdoor station Configuration procedure Simplified Mode 1 Press the key to be programmed and hold it down for at least 6 s 2 When the indoor station has emitted a beep release ...

Страница 21: ... station emits two beep in sequence apart duration 0 5 s 3 Release the key being programmed 4 From the outdoor station concerned within 60s make a call to the indoor station being programmed 5 The indoor station receives the call and confirms that the key has been programmed with a new beep 4 5 1 6s beep beep 2 2s 2 x beep 3 60 s N B for entrance panels with push buttons press the call button corr...

Страница 22: ...tion procedure Simplified Mode 1 Press the key you want to reprogramme to its default value and hold it down for at least 6 s 2 After 6 seconds the indoor station emits a beep high tone 3 Release the key you want to reset then press it again to return it to its default setting The device emits a confirmation tone that the key has been reset Alternative configuration procedure Simplified Mode 1 Pre...

Страница 23: ...urations This process is recommended when you want to change identification code of a previously programmed indoor station and you do not want to retain the operating configuration of the device Configuration procedure Simplified Mode 1 Press and hold down the lock release key for 6 s When the time runs out the indoor station will emit a beep 0 5 s 2 Continue holding down the lock release key Afte...

Страница 24: ...erts in the switchboard The sending of messages never terminates It continues until the end of the service described in the next point unless the switchboard is powered off or removed from the system in which case the indoor station after 5 unsuccessful attempts starting from the first timeout of 120 seconds will return to standby mode and the Alert signal is no longer sent to the user 6 If the sw...

Страница 25: ...e Device Configuration window Perform the configuration and click on to transfer it to the video entryphone Firmware Updating Advanced programming can be done using the software modifying the configurations of all keys creating Groups enabling and disabling functions To update the device 1 disconnect it from the Due Fili Plus bus 2 connect it to the PC via USB 3 start the WinBoot update within 30 ...

Страница 26: ...Proper sorted waste collection for subsequent recycling processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and or recycling materials used in manufacture Regulatory compliance EMC directive RoHS directive Standards EN 62368 1 EN 61000 6 1 EN 61000 6 3 EN IEC...

Страница 27: ...IT 27 7539 Tab Free ...

Страница 28: ...49400581F0_MU_EN 00 2111 Viale Vicenza 14 36063 Marostica VI Italy www vimar com ...

Отзывы: