28
RS10
P arameter numb er D escription
Settab le v alues
D ef ault v alue
Modif ied
v alue
P 01
Enables automatic closing
ON/OFF
OFF
P 02
Sets the automatic closing time
2-600 seconds
60 seconds
P 03
APCH input operation
1= when opening, APCH input not active (condo)
2 = APCH as sequential (open, stop, close, open)
3 = APCH as sequential (open, close, open...)
4 = APCH commands only opening, APED commands only
closing
1
P 04
Pre-flash
OFF= pre-flash off
ON= pre-flash on (flashing output activated for 3 seconds
before the movement of the gate)
ON
P 05
Instant closure
ON= with the gate opening or open on disengaging the
PHOTO input (terminal 22) the gate closes 3 sec. after com-
pleting opening
OFF= normal operation
OFF
P 06
Logic of the STPA input
0= microswitch sensitive edge (the operation of this input
immediately reverses the movement for 1.5 seconds and then
stops the gate
1= resistive sensitive edge (balanced with 8.2Kohm resistance),
the operation of this input immediately reverses the movement
for 1.5 seconds and then stops the gate
2= photocell as internal protection (if engaged it stops the
gate, until it is disengaged, then it continues opening)
0
P 07
AUX output operating mode
OFF = flashes slowly during gate opening and is on steady
when the gate is open and stationary, flashes rapidly during
closing and is off when the gate is closed and stationary
ON = flashes while the gate is moving and is off when the
gate is stationary
OFF
P 08
Enables checking the safety
inputs
0 = input check off
1= check only on PHOTO input
2= check only on STPA input
3 = check on PHOTO and STPA inputs
0
P 09
Slowdown distance when closing
From 0 to 100%
0%= no slowdown when closing
100% = slowdown for the whole closing distance
30%
P 10
Slowdown distance when opening
From 100 to 0%
100%= no slowdown when opening
0% = slowdown for the whole opening distance
70%
P 13
Opening deceleration speed
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
45%
P 14
Closing deceleration speed
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
45%
P 15
Motor force
From 0 to 100%
0%= minimum force
100% = maximum force
50%
P 16
Force on obstacle detection
(parameter can only be used with
encoder)
From 0 to 100%
0% = minimum force (maximum obstacle sensitivity)
100% = maximum force (minimum obstacle sensitivity)
50%
P 17
Braking
From 0 to 25
0 = minimum braking force
25 = maximum braking force
5%
P 18
Gate opening direction
L = gate opening to the left
R = gate opening to the right
L
P 2 0
Selects the operation of the
second radio channel
2CAN= activates the 2CH output
PEDO = controls pedestrian opening while the 2CAN output
functions as a courtesy light timed at 60 seconds
PEDO
P 2 1
Channel 2 output activation time
From 1 to 60 seconds
1 sec.
P 2 2
Pedestrian opening distance
From 0 to 100% of total gate travel
50%
P 2 4
Break-out on starting
OFF = gate starts with the force regulated with parameter
P15
ON = gate starts for 1 second at maximum power to then
return to the force regulated with parameter P15
ON
P 2 5
Manned, APCH controls opening
by keeping the button pressed,
PED controls closing by keeping
the button pressed
OFF: function disabled
ON: function active if the safety devices are open (PHOTO
and STPA) gate starting is delayed by 3 seconds from actua-
ting the button
OFF