RS02
Number
of parameter Description
Settable values
Default
value
Modified
value
P01
Enables automatic closing
ON/OFF
ON
P02
Sets the automatic closing time
2-600 seconds
60 seconds
P03
AP/CH input operation
1= when opening, AP/CH input not active (condo)
2=AP/CH as sequential (open, stop, close, stop..)
3=AP/CH as sequential (open, open, close..)
1
P04
Pre-flash
ON/OFF
ON
P05
Closing after photocell disengage-
ment
ON/OFF
OFF
P06
Type of safety device connected to
the STPA input
1= photocell as protection on opening
(if engaged it stops the gate/barrier, until it is disengaged, and then it
continues in the same direction)
2= microswitch sensitive edge
3= resistive sensitive edge (balanced with resistance (8.2Kohm)
4= photocell as internal protection (if engaged it stops the gate/barrier,
until it is disengaged, then it continues opening)
1
P07
AUX output operating mode
1= disabled
2= flashes while the gate/barrier is moving
3= flashes while the gate/barrier is moving and stays on steady when
the gate/barrier is stationary
2
P08
Enables photocell control
0= Control disabled, 1= Control on FOTO input
2= Control on STPA input, 3= Control on STPA and FOTO inputs
0
P09
Slowdown distance when closing
0-150cm
73cm
P10
Slowdown distance when opening
0-150cm
49 cm
P11
Opening speed
50-100%
100%
P12
Closing speed
50-100%
100%
P13
Opening deceleration speed
20-75% - Minimum speed 20%
50%
P14
Closing deceleration speed
20-75% - Minimum speed 20%
50%
P15
Motor force
Min. 1-10 max
5
P16
Intensity of stopping with opening
limit switch tripping
0-10
0= instantaneous stop
10= soft stop
5
P17
Intensity of stopping with closing
limit switch tripping
0-10
0= instantaneous stop
10= soft stop
5
P18
Separate buttons
0= AP/CH controls complete opening and closing of the gate/barrier,
P
ED controls partial opening and closing of the gate/barrier
1= input AP/CH, controls opening only and input
PED, controls closing only
2= input AP/CH and the button of the remote control saved as CH1
controls opening only and the PED input and the button of the remote
control saved as CH2 controls closing only
0
- the gate/barrier opens and closes completely and the display shows 4 dots (reading the current thresholds)
- when completely closed, the display shows END,indicating that the travel has been saved correctly.
8.4 PAR:
Used to modify all the parameters of the control unit, press the UP button until PAR appears on the display, confirm with the OK button to dis-
play the list of parameters, the display will show P 01 (parameter number 1), the UP or DOWN button lets you scroll through the list of parameters (see
parameter table).
Parameter table
Press the button until you
see the parameter to be
modified
x4
EN
Содержание ELVOX RS02
Страница 128: ...126 RS02 CHIUSURA 7 31 7 1 APERTURA APERTURA 31 OFF 31 ON EL...
Страница 129: ...127 RS02 x2 2 RAD OK 1CH AP CH OK 4 10 4 1 AP CH 2 3 001 002 200 12 bit 1 2 3 1 2 3 4 5 OK AP CH 2 50 cm END 7 2 APCH EL...
Страница 131: ...129 RS02 Premendo 1 volta UP Premendo 2 volte UP Premendo 3 volte UP OK AP CH 2 50 cm END 8 2 RAD 4 1 UP 2 UP 3 UP EL...
Страница 139: ...137 RS02 11 LED STOP STPA FOTO LED STOP STPA FOTO dip 200 LED STOP STPA FOTO 24 led enc a enc b 13 14 25 10 15 EL...
Страница 144: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49400422A0 03 1710...