4.1- Power supply line wiring
Inside the transformer compartment there is a terminal with a 2 AT protection fuse, connect the phase in the corresponding pole to the fuse.
4.2- Wiring for flashing light, courtesy light and gate/barrier movement warning light
Terminals
Description
Function
1-2
Motor output
Output for controlling electric motor 12 V dc rated power 50 W
(terminal number 1 white, terminal number 2 brown)
3-4
Courtesy light or second radio channel Output 12 V dc maximum load 65mA, can be programmed as a timed output (60 seconds) or
second radio channel output (3 = GND / 4 = +12 V dc).
4-5
Warning light output
Output 12 V dc maximum load 65mA, flashes slowly when opening, on with stationary open
gate/barrier, flashing fast when closing and off with gate/barrier closed (4= +12 V dc / 5= GND).
6-7
Accessories power supply output
Output 12 V dc maximum 300 mA for supplying the photocells and accessories
(6 = +12 Vdc, 7= GND)
8-9
Output for flashing light
Output 12 V dc maximum load 15 W for flashing light (8 = GND, 9 = + 12 V dc).
Fuse 2 A L 250 V (Mains: 230 V, 240 V)
Fuse 4 A L 250 V (Mains: 110 V, 117 V, 125 V)
Mains
Transformer
12 Vdc 15 W max
12 V dc 65 mA max
Courtesy light or sec-
ond radio channel
12 V dc 65 mA max
gate/barrier move-
ment warning light
Power supply output for ac-
cessories 12V dc 300mA
-
+ -
-
+
- +
Electric
motor
Fig. 4
Fig. 5
white
brown
N.B.:
Do not change the motor output wiring (terminals 1 and 2) the parameter number 31 selects the direction of opening
10 11 12 13 14 15 16
COM
APCH
APED
COM
ST
OP
FOT
O
STP
A
CN2
Input description table:
The control unit is supplied with jumpered normally closed inputs (STOP, FOTO and STPA) remove the jumper from the input you are going to use.
Terminal number
Description
Input type
10-13-18
Control inputs common (permanent GND)
-
11
Sequential control input, for
controlling the complete travel of the gate/barrier
Normally open
12
Sequential control input, for
controlling the pedestrian travel of the gate/barrier
Normally open
14
Input for stopping the gate/barrier
Normally closed
15
Photocell input, active during gate/barrier closing
Normally closed
16
Input for edges or internal photocell, active during gate/bar-
rier closing and opening
Configurable: normally closed or
balanced at 8.2 K ohm
17
Opening limit switch input with parameter 31 OFF
Closing limit switch input with parameter 31 ON
Normally closed
19
Closing limit switch input with parameter 31 OFF
Opening limit switch input with parameter 31 ON
Normally closed
EN
Содержание ELVOX RS02
Страница 128: ...126 RS02 CHIUSURA 7 31 7 1 APERTURA APERTURA 31 OFF 31 ON EL...
Страница 129: ...127 RS02 x2 2 RAD OK 1CH AP CH OK 4 10 4 1 AP CH 2 3 001 002 200 12 bit 1 2 3 1 2 3 4 5 OK AP CH 2 50 cm END 7 2 APCH EL...
Страница 131: ...129 RS02 Premendo 1 volta UP Premendo 2 volte UP Premendo 3 volte UP OK AP CH 2 50 cm END 8 2 RAD 4 1 UP 2 UP 3 UP EL...
Страница 139: ...137 RS02 11 LED STOP STPA FOTO LED STOP STPA FOTO dip 200 LED STOP STPA FOTO 24 led enc a enc b 13 14 25 10 15 EL...
Страница 144: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49400422A0 03 1710...