32
RS02
CHIUSURA
7.3 Example of the procedure for changing the automatic closing time:
Press the
UP
button 4 times, the display will show
PAR
(parameters)
Press
OK
, the display will show
P01
Press the
UP
button once, the display will show
P02
(automatic closing time)
Press the
OK
button, the display will show the automatic closing time
With the
DOWN
or
UP
button you can vary the automatic closing time
Press the
OK
button to confirm and save the modified value
8- Full description of the programming menu.
The programming menu is divided into 3 levels: first the main level, second the parameters level and third the values level
Main menu:
Display Message
Description
LRNE
Learning travel with quick programming (see section 6)
RAD
Remote control management
LRN
Learning travel with custom programming
PAR
Used to modify all the parameters of the control panel
DEF
Used to go back to the default values
CNT
Used to view the manoeuvres carried out
ERR
Used to view a list of the last 9 errors or malfunctions
PASS
Control panel protection level setting
After selecting the desired item from the main menu by pressing the
UP
or
DOWN
button, confirm by pressing
OK.
8.1 LRNE: quick procedure for programming gate/barrier travel
1
2
3
4
5
6
1
2
3
CLOSING
x4
EN
Содержание ELVOX RS02
Страница 128: ...126 RS02 CHIUSURA 7 31 7 1 APERTURA APERTURA 31 OFF 31 ON EL...
Страница 129: ...127 RS02 x2 2 RAD OK 1CH AP CH OK 4 10 4 1 AP CH 2 3 001 002 200 12 bit 1 2 3 1 2 3 4 5 OK AP CH 2 50 cm END 7 2 APCH EL...
Страница 131: ...129 RS02 Premendo 1 volta UP Premendo 2 volte UP Premendo 3 volte UP OK AP CH 2 50 cm END 8 2 RAD 4 1 UP 2 UP 3 UP EL...
Страница 139: ...137 RS02 11 LED STOP STPA FOTO LED STOP STPA FOTO dip 200 LED STOP STPA FOTO 24 led enc a enc b 13 14 25 10 15 EL...
Страница 144: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49400422A0 03 1710...