Graphic User Interface (GUI) for IP Speed Dome
EN
2. Set the alarm line number and direction. Up to 4 lines can be added. Multiple lines cannot be added simultaneous-
ly.
Direction
: A<->B, A->B and A<-B optional. This indicates the direction of someone or a vehicle crossing over the
alarm line.
A<->B
: Alarms will be triggered when someone or a vehicle crosses over the alarm line from B to A or from A to B.
A->B
: Alarms will be triggered when someone or a vehicle crosses over the alarm line from A to B.
A<-B
: Alarms will be triggered when someone or a vehicle crosses over the alarm line from B to A.
3. Set the detection area by clicking the buttons of area (1) and then click “Lock” to lock the area.
Note
: The PTZ will not be controlled if you click “Lock” here. Click “Unlock” and then click the buttons of area (1) to
move the PTZ camera. Clicking the “Unlock” button suspends object tracking until you click the “Lock” button.
4. Click the “Draw Area” button and then drag the mouse to draw a line in the image. Click the “Stop Draw” button to
stop drawing. Click the “Clear” button to delete the lines. Click the “Save” button to save the settings.
-
Schedule Configuration
Set the schedule of the line crossing alarm. The setup steps of the schedule are the same as the Motion detection
setup schedule.
5.4.7 Intrusion
Intrusion
: Alarms will be triggered if the target intrudes into the pre-defined areas.
Go to Config
Event
Intrusion interface as shown below.
-
Detection Configuration
Enable intrusion detection, select the snapshot type and the detection target and set the alarm holding time and
alarm trigger options. The detection setup steps are the same as line crossing detection. Please refer to the detection
configuration of line crossing detection for details.
-
Area Configuration
1. Click the “Area” tab to go to the interface as shown below.
Содержание Elvox 46235.030D
Страница 1: ...Graphic User Interface GUI for IP Speed Dome Installation and operation manual ...
Страница 38: ... 38 Graphic User Interface GUI for IP Speed Dome EN ...
Страница 69: ... 69 Graphic User Interface GUI for IP Speed Dome EN ...
Страница 70: ...49401712A0_EN 00 2109 Viale Vicenza 14 36063 Marostica VI Italy www vimar com ...