28
-
h HEAT.
(hours of operation in which the timer-thermostat has
operated on heating);
-
h AIRC.
(hours of operation in which the timer-thermostat has
operated on air-conditioning);
-
RESET h.
Press the
selection button and the display will
show
RESET
blinking; press the
selection button again if
you want to reset the data for
h HEAT
and
h AIRC.
and restart
with a new count.
10.
OPERATION OF THE TIMER-THERMOSTAT
WITH THE RADIO MODULE.
The timer-thermostat 01911, after installing the radio module
01921.1, can be configured for radio control of an actuator 01923 or
01924 connected to the boiler or to the fan coil unit.
The option
CONFIG. RF
is only displayed when the radio module
01921.1 has been inserted in the timer-thermostat in place of the
relay module; this condition is shown on the display with the symbol
; displaying the symbol therefore indicates installation of the
radio module 01921.1 and, more generally, the lack of the relay
module.
Correct use of the radio module 01912.1 requires appropriate
configuration.
Access the
SETTINGS
menu and press the
selection button in
correspondence with
CONFIG. RF
; the display will show:
Using the rotary knob, set the identification number of the channel to
configure for using the actuator 01923 or 01924.
Press the
selection button and the display will show:
Figure 31
Содержание 01911
Страница 1: ...01911 Surface electronic chronothermostat Instruction handbook CLIMAPIÙ ...
Страница 2: ...Space for noting the three digit PIN number used as the lockout password ...
Страница 4: ......
Страница 8: ...4 Figure 2 Figure 3 ...
Страница 9: ...5 Figure 4 Figure 5 ...
Страница 11: ...7 83 5 mm 60 mm Figure 6 ...