OPERATION, MAINTENANCE AND SERVICING

Installation and service of cooling equipment can be hazardous due to electrical components, moving fan blades, presence of water, 

etc. Only trained and qualified personnel should install, repair or service refrigeration sections. Use only factory authorized replacement 

parts and accessories when servicing this equipment.

Owners may perform basic maintenance including: cleaning, rinsing the intake screen, pump intake and sump area, float adjustments, winter 

shut-down, draining, and spring start-up. Other operations should be performed by trained service personnel. When working on cooling 

equipment, observe warnings in the literature, tags and labels attached to the equipment, and any other safety precautions that apply. 

Follow all safety codes. Wear safety glasses and work gloves when servicing the equipment.

Standard Unit Cleaning

Mineral deposits are automatically controlled by the unit’s self-cleaning systems and routine annual maintenance. If the flush system fails, 

excessive minerals can build up and a more stringent cleaning may be required. If so, please see “cleaning excessive mineral deposits”. 

Please note some scale on the copper coils is desirable because it increases the surface “wetting” and improves performance. Following 

is a step-by-step procedure for normal sump cleaning.

Regular maintenance and/or service is the key to long, trouble-free performance from your unit. The following schedule will help you 

maintain an efficient unit with good appearance. Adhering to the suggested schedule of component replacement at the start of the 

season will reduce in-season maintenance requirements. 

 

 

  CAUTION: Wear gloves and safety glasses when performing regular maintenance.

Seasonal shut-down at the end of air conditioning season

1.  Turn off the thermostat.
2.  Turn off the electricity to the unit using the wall mounted disconnect.
3.  Turn off the water supply valve.
4.  Remove the sump drain cap. Rinse off the intake screens, flush the base pan and the pump screens.
5.  Leave the sump drain cap removed so the pan drains throughout the winter.

Seasonal start-up at the beginning of the air conditioning season

Check the following and adjust, clean or replace as needed.

1.  Turn off the electricity to the unit using the wall mounted disconnect.
2.  Rinse intake screens from the inside out.
3.  Rinse out base to remove debris and minerals.
4.  Install sump drain cap and tighten until it is firmly seated.
5.  Turn on water supply valve.
6.  Check water level (should be 5” deep) and make sure unit is level. Adjust float if needed.
7.  Turn on electrical wall disconnect.
8.  Turn unit on by lowering the temperature setting several degrees below the actual room temperature.

2

Содержание AquaChill AQV

Страница 1: ......

Страница 2: ...manufactured by villara corporation REV 4 5 18 AQV homeowner s operation manual Now You re Cooler ...

Страница 3: ... by 25 40 We are passionate about our customers and assisting in the environmental concerns of today The AquaChill is an important step towards our goal of complete customer satisfaction and doing our part to conserve energy Villara Building Systems is honored and delighted to provide this energy efficient technology to you Please contact us if you have any questions or concerns regarding your new...

Страница 4: ......

Страница 5: ......

Страница 6: ...owner quick tips 7 Electrical wiring diagram 8 System diagram 8 Parts Diagram 9 Warranty information 10 Villara Corporation works continually to improve its products As a result the design and specifications of the AquaChill unit may vary slightly Please contact Villara s Manufacturing Department at 916 646 2700 for specific information on current product design and specifications Statements and o...

Страница 7: ... Custom Polyethylene cabinet with UV resistance Sound absorbing construction materials Easy access door for servicing Water Requirements Unit requires a water shut off valve and 1 4 water line Safety Considerations WARNING or DANGER denotes safety alerts regarding hazards that will result in severe injury or death CAUTION denotes alerts to unsafe practices that can result in minor personal injury ...

Страница 8: ...or prov inces do not allow limitations on how long an implied warranty or condition last so the above may not apply to you The expressed warran ties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever Villara Corporation will not be responsible for 1 Damage or repair required as a consequence of faulty installation or ...

Страница 9: ... COIL ASSEMBLY 5 T 8 ROW 8 TOP OF MAIN BODY OF CASING PARTS DESCRIPTION ITEM AQUACHILL PARTS DIAGRAM PARTS BREAKDOWN FRONT VIEW 1 ELECTRICAL CONTROL BOX 2 CONTACTOR 3 TIME DELAY 4 CAPACITOR COMPRESSOR FAN 5 COMPRESSOR SIZE PER MODEL 6 VALVE CARRIER LIQUID LINE 7 VALVE CARRIER SUCTION LINE 8 BALL VALVE FLOAT ASSEMBLY 9 NU CALGON PURGE VAP WATER TREATMENT 10 DRIP DRAIN PURGE ASSEMBLY 11 LOW LEVEL PR...

Страница 10: ...ves performance Following is a step by step procedure for normal sump cleaning Regular maintenance and or service is the key to long trouble free performance from your unit The following schedule will help you maintain an efficient unit with good appearance Adhering to the suggested schedule of component replacement at the start of the season will reduce in season maintenance requirements CAUTION ...

Страница 11: ...ake sure to turn off the electrical disconnect on the wall before working on the unit When you put your hands in the unit you run the risk of injury if the unit is accidentally turned on from inside the house Never wear slick soled shoes when working on a roof You may slip when you least expect it PERIODIC SERVICE OR MAINTENANCE Service Needs Semi Annual Start up Semi Annual Shut down Rinse off fa...

Страница 12: ...AIR WIRING DIAGRAM DANGER of serious injury or death Disconnect all electricity before servicing WARNING There may be multiple disconnects on each unit and all disconnects must be turned off Check local codes for wiring Wiring connections and adjustments should be made ONLY by qualified persons Amperage must not exceed total nameplate ratings of the electrical equipment SYSTEM DIAGRAM Ultra effici...

Страница 13: ...e a water valve on the copper water line it is critical that this valve is on during the air conditioning season The base pan has a brass drain plug The drain cap is unscrewed to drain the reservoir during servicing or to drain the reservoir during winter During the summer the drain cap should be in place and tightened properly Preparing your AquaChill for Winter At the end of the cooling season w...

Страница 14: ... up connection to non softened water 4 Add EVAPTreat water treatment EVAPTreat product lasts one season 1 Drain flush and clean reservoir Check purge flow operation Refer to unit water treatment bulletin 1 Flush or rinse out base until soap residue is removed TROUBLE SHOOTING Possible Causes 1 Thermostat setting 2 No electrical power 3 Fuse blown 4 Circuit breaker tripped 5 Faulty wiring or shorts...

Страница 15: ...15 20minutes forthewatertemperaturetoreach a stable temperature when the unit is operating AQV30X0101 piston size 65 AQV41X0101 piston size 73 WATER TREATMENT Chemical water treatment is usually not required The chlorine and other treatments added to city water are generally more than adequate biocide treatments for residential applications The purge control is provided to reduce the buildup of mi...

Страница 16: ...rgevalveadjustmentsshouldbe done slowly as it will take 30secondsfortheinternal water level to adjust to the new setting After several minutes measure the purge rate using the plug elbow as a convenientlocation It is recommended to take several 1 minute measurementsandaveragetheresults Agoodtechniqueistotake3one minutemeasurements over5 10minutesofoperation Ifadjustmentisrequired makesmalladjustme...

Отзывы: