![Viking VX 900 MHz LTR Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/viking/vx-900-mhz-ltr/vx-900-mhz-ltr_user-manual_1025501126.webp)
ALIGNMENT AND TEST PROCEDURES
7-14
October 1999
Part No. 001-2009-201
7.6 FULL REPEATER ALIGNMENT
7.6.1 PERFORMANCE TEST PROGRAM
1. Select the TEST - FULL REPEATER - ALL TEST
and press Enter.
7.6.2 REPEATER SETUP
The Viking VX repeater has been pretested at the
factory, therefore only performance tests are required
to check the repeater. Refer to test setup diagrams for
equipment and cabling diagram.
1. Pretest the MPC, IAC, MAC and RFIB per their
individual board level test procedures.
2. Pretest the Power Amplifier, Exciter, Receiver and
Chassis per their individual test procedures. The RF
modules should be tuned for the customer specified
T/R frequency pair. If not, retune per individual test
procedures.
3. Assemble the Transceiver to the Power Amplifier
and insert into the chassis along with the Power Sup-
ply, MPC and MAC. Slide the IAC partially into the
card rack but do not engage the locking level. Con-
nect the OCXO input to the high stability 1.25 MHz
source.
4. Engage the locking lever of the IAC and turn on the
repeater power supply switch (S508) in the IAC or
engage the locking lever (see Figure 7-18).
The operating code has been programmed at the
factory. The parameters are programmed into the
MPC. If these parameters have changed or are incor-
rect, exit this test and reprogram the repeater.
It may be necessary to remove the RF assembly
from the chassis and connect via extension cables for
some of the tests or adjustments.
NOTE: Unless specifically stated otherwise, all mea-
surements are to be done per the latest TIA docu-
mented procedures. All audio generators and audio
voltmeters are unbalanced unless specifically stated
otherwise.
7.6.3 TRANSMITTER TEST/ADJUSTMENTS
NOTE: 2000 Series OCXO must be powered up for 1/
2 hour or longer to stabilize frequncy.
Transmit Mode
1. Press the space bar to key the repeater.
2. The Transmit LED on the IAC should turn on to
indicate the repeater is transmitting.
3. Press the space bar to unkey the repeater.
Transmitter Output Power Test
1. Press the space bar to key the repeater.
2. Check the transmit output power. The power can be
adjusted from the computer using the cursor Up/Dn
and PgUp/PgDn keys. Calibrate test equipment for
±
2W.
3. Press the space bar to unkey the repeater.
NOTE: This adjustment will alter the repeater’s stored
default value.
7.6.4 RECEIVER TESTS/ADJUSTMENT
Receiver TCXO Frequency Test
1. Check the receiver injection frequency by using a
"sniffer" pickup loop, or RF probe connected to a
suitable frequency counter placed near L210 in the
Receiver (see Section 7.2.4). The frequency should
be the Channel Frequency minus 52.95 MHz
(
±
90 Hz).
2. Tune Y201 (TCXO) on the Receiver at TP1 for 3.5V
DC
±
0.05V (response time is very slow).
Receiver Audio Distortion Measurement
1. Adjust the RF generator for 100
µ
V output with a 1
kHz tone at
±
1.5 kHz deviation.
2. Insert test cables into J100/J103 on the MAC and
connect to an AC voltmeter.
Содержание VX 900 MHz LTR
Страница 2: ...1 2 October 1995 Part No 001 2008 202...
Страница 4: ...1 4 October 1995 Part No 001 2008 202...
Страница 24: ...INTRODUCTION AND OPERATION 1 10 October 1999 Part No 001 2009 201...
Страница 26: ...INTRODUCTION AND OPERATION 1 12 October 1999 Part No 001 2009 201...
Страница 40: ...INSTALLATION 2 14 October 1999 Part No 001 2009 201...
Страница 56: ...PULL DOWN MENUS 4 12 October 1999 Part No 001 2009 201...
Страница 60: ...REPEATER PROGRAMMING 5 4 October 1999 Part No 001 2009 201...
Страница 142: ...SERVICING 8 8 October 1999 Part No 001 2009 201...
Страница 191: ...SCHEMATICS AND COMPONENT LAYOUTS 10 9 October 1999 Part No 001 2009 201 Figure 10 14 RECEIVE VCO COMPONENT LAYOUT...
Страница 234: ...900 MHz CHANNEL FREQUENCY CHART A 6 October 1999 Part No 001 2009 201 This page intentionally left blank...