7
PROXIMITY TO SIDE CABINET INSTALLATION
1.
This range may be installed directly adjacent to existing 36" high base cabinets.
IMPORTANT-
the top grate support
MUST
BE 3/8" above the adjacent base cabinet countertop. This may
be accomplished by raising the unit using the adjustment spindles on the legs. (The countertops
CANNOT
be higher than 37 1/2" due to the high BTU burners.)
2. The
range
CANNOT
be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side
vertical surfaces above 36" high. There must be a minimum of 6" side clearance from the range to such
combustible surfaced above the counter height.
3.
Within the 6" side clearance to combustible vertical surfaces above 36", the maximum wall cabinet depth must
be 13" and wall cabinets within 6" side clearance must be 18" above the 36" high countertop.
4.
Wall cabinets above the range must be a minimum of 36" above the range cooking surface for the full width of
the range.