32
TROUBLE SHOOTING GUIDE
PROBLEM
PROBABLE
CAUSE
CORRECTION
5. Gas flows to bake/broil
5A. Ignitor position too far
5A. Reposition ignitor closer to the bake/broil
burner but does not light
from burner.
burner.
5B. Dirt or grease in orifice.
5B. Clean the orifice.
5C. Insufficient gas pressure.
5C. Check for correct gas pressure . Pressure
should be 5” WCP for natural gas or 10”
WCP for LP gas.
5D. Gas supply.
5D. Check oven shut off valve located on the
manifold.
6. Fan motor does not operate.
6A. No power to the fan motor.
6A. Check for 120VAC supplied to the fan
motor. If no voltage is present, check the
selector switch for continuity and, check
for broken wiring between the selector
switch and fan motor. If voltage is
present at the fan motor proceed to 6B.
6B. Defective fan motor winding
6B. Check the motor winding for continuity.
or frozen motor shaft.
Check for a frozen motor shaft and check
check for broken wiring between the
motor and neutral terminal block.
7. Oven light does not operate.
7A. Burned out bulb.
7A. Replace bulb.
7B. Defective light switch.
7B. Check light switch contacts for continuity.
7C. Defective light socket.
7C. Check for 120VAC the light socket
terminals. If voltage is present, replace
the light socket. If no voltage is present,
check for broken wiring between the light
switch and light socket.
8. Oven light stays on.
8A. Defective light switch.
8A. Check light switch contacts for continuity
Replace
light
switch.
9. Oven indicator light does
9A. No power to the indicator
9A. Check for broken wiring between the
not come on.
Light.
Thermostat and indicator and from the
indicator to the neutral terminal block.
9B. Defective indicator light.
9B. Check for 120VAC at the indicator
terminal. If voltage is present, replace
the
indicator
light.
10. No spark at top burners.
10A. No power.
10A. Check power source.
10B. Broken innitor.
10B. Replace spark electrode.
10C. Wire connection.
10C. Check connection between spark
Pinched wire.
electrode and spark module.
10D. Valve switch
10D. Check continuity on valve switch. It no
continuity replace switch. If continuity
checks ok, check all wire connections.
10E. Defective spark module.
10E. Replace spark module.
11. Delayed ignition on top
11A. Electrode position.
11A. Align electrode with burner port.
burner.
11B. Clogged ports on burner.
11B. Clean or replace burner.
Содержание VGR30
Страница 1: ...SERVICE MANUAL FREE STANDING GAS RANGE...
Страница 4: ...4...
Страница 25: ...25 COMPONENT LOCATION...
Страница 35: ...35 GRIDDLE REPAIR KIT FOR 12 VIKING RANGETOP ONLY...
Страница 36: ...36 GRIDDLE REPAIR KIT FOR 24 VIKING RANGETOP ONLY...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...38...