Selector Convection Cook position closes Switches 5-L2 and 6-1. 6-1 powers the Convection Fan
through L1- at 120v. The Thermostat closes Switch Cy1-Cy2, which cycles with the Oven
temperature, powering the R1 relay and the Oven Cycle Light. When Relay R1 closes, it powers the
Convection Element (208 – 240).
240 Volts
208 Volts
240v
OHMS [R] WATTS [W] AMPS [I]
Convection element
26
2220
9.25
Total amps
9.25
208v
OHMS [R] WATTS [W] AMPS [I]
Convection element
26
1665
8.00
Total amps
8.00