![Viking VCBB360L Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/viking/vcbb360l/vcbb360l_service-manual_1025453051.webp)
51
ICEMAKER
To avoid property damage, test for
water leaks after repair or replacement
of water valve. Do not over tighten
connection to household water supply.
Water Valve
Water valve has 1 solenoid. Valve has 80 mesh
screen water strainer. When tan encapsulated
solenoid is energized, the amount of water entering
icemaker mold is directly proportional to length of
time water valve switch is held closed by timing cam.
Inside valve is a flow washer which acts as a water
pressure regulator. Proper icemaker fill is 140cc
±
10cc at 7.5 seconds of water fill at an inlet pressure
ranging from 20 to 120 psi (1.4 to 8.2 bar).
Wire Harness
A non-resettable thermal fuse micro device 170
°
F
(78
°
C) is spliced into red wire of icemaker wiring
harness. Excessive heat can cause no ice production.
Replacing wiring harness will only temporarily solve
the problem. Replace icemaker thermostats.