30
Component Testing
Compressor Description
Test Procedure
Switch, showroom ON position completes circuit to Check resistance at test points.
SPDT
lights and display only
Showroom operation –E3 at high voltage board to pin
3 (blue/white wire) at high voltage wire harness.
OFF position completers circuit
for normal operation.
Unit run—E9 at high voltage board to pin 3
(blue/white wire) at high voltage wire harness.
Unit shipped with switch in OFF
position.
Thermistor
Senses temperature within
Check resistance across terminals. See Technical Date
Refrigerator and freezer.
Sheet for bell curve resistance chart at given temperature.
Thermostat
Thermostat is in a series circuit
With power off and evaporator coil below freezing
with high voltage board and
thermostat should check continuous when checked
defrost heater.
with ohmmeter. See “Heater, evaporator (defrost)”
section for additional tests.
Controls the circuit through
defrost terminator to defrost
heater. Opens and breaks circuit
when thermostat senses present
high
voltage.
After defrost thermostat opens
thermostat remains open until
end of defrost cycle and
refrigerator starts cooling again.
When defrost thermostat senses
a preset low temperature and
closes.
Valve, water
controls water flow to the ice
Check resistance across coil windings. See Technical
Maker.
Data Sheet for valves for model being serviced.