background image

IMPORTANT–

Please Read and Follow!

3

2

Table of Contents

• Make sure that incoming voltage is the same

as unit rating. An electric rating plate
specifying voltage, frequency, wattage,
amperage, and phase is attached to the
product.

• To reduce the risk of fire, electric shock, or

injury to persons, installation work and
electrical wiring must be done by qualified
people in accordance with all applicable
codes and standards, including fire-rated
construction.

• The installer should leave these instructions

with the consumer who should retain them
for local inspector’s use and for future
reference.

It is your responsibility to:

• Comply with installation specifications and

dimensions

• Properly install unit
• Remove any moldings or decorative panels

that prevent the unit from being serviced

• Make sure that you have these materials (not

provided with your unit), which are necessary
for proper installation:

•1/4” (6 mm) copper tubing with shutoff

valve

•6– #8 x 3” (7.6 cm) wood screws (longer

screws may be required)

•1– saddle valve (do not use self-piercing

feature of the valve)

• Assure that floor will support unit, door

panels and contents (approximately 1200
pounds [540 kg])

• Provide a properly grounded electrical outlet
• Assure that location will permit appliance

doors to open 90˚ minimum

W A R N I N G

TIP OVER HAZARD

Appliance is top
heavy and tips easily
when not completely
installed. Keep doors
closed until appliance
is completely installed
and secured per installation instructions.

Use two or more people to move and
install appliance. Failure to do so can
result in death or serious injury.

W A R N I N G

ELECTRICAL SHOCK

HAZARD

Disconnect power or turn
power disconnect switch to
OFF position before removing
top grille. Failure to do so can
result in death or electrical shock

Your safety and the safety of others is
very important.

We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.

This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.

All safety messages will be preceded by the
safety alert symbol and the word“DANGER”
or “WARNING.” These words mean:

D A N G E R

You will be killed or seriously injured if

you don’t follow instructions.

W A R N I N G

You can be killed or seriously injured if

you don’t follow instructions.

All safety messages will identify the

hazard, tell you how to reduce the chance

of injury, and tell you what can happen if

the instructions are not followed.

Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent
tipping. Use cardboard shipping material or plywood under unit until it is installed in the
operating position to protect floor surface.

Warnings & Important Information_____________________________________________________ 3
Professional & Professional Integrated Side-by-Side

Dimensions & Specifications (Professional 42” & 48”) ________________________________ 4
Dimensions & Specifications (Professional Integrated 42” & 48”) _______________________6
Cutout Dimensions (42”)__________________________________________________________ 8
Anti-Tip Dimensions (42”) _________________________________________________________ 9
Cutout Dimensions (48”)_________________________________________________________ 10
Anti-Tip Dimensions (48”)________________________________________________________ 11

Professional & Professional Integrated Bottom-Mount

Dimensions & Specifications (36”)_________________________________________________ 12
Cutout Dimensions (36”)_________________________________________________________ 14
Anti-Tip Dimensions (36”)________________________________________________________ 15

Cabinet Information (Professional) ____________________________________________________ 16
Cabinet Information (Professional Integrated) __________________________________________ 18
Designer Side-by-Side

Dimensions & Specifications (42” & 48”)___________________________________________ 20
Cutout Dimensions (42”)_________________________________________________________ 22
Anti-Tip Dimensions (42”)________________________________________________________ 23
Cutout Dimensions (48”)_________________________________________________________ 24
Anti-Tip Dimensions (48”)________________________________________________________ 25

Designer Bottom-Mount

Dimensions & Specifications (36”)_________________________________________________ 26
Cutout Dimensions (36”)_________________________________________________________ 28
Anti-Tip Dimensions (36”)________________________________________________________ 29

Cabinet Information (Designer)_______________________________________________________ 30
Custom Side Panel Dimensions (Professional)__________________________________________ 32
Custom Side Panel Dimensions (Designer & Professional Integrated) _____________________ 33
General Information ________________________________________________________________ 34
Unpacking & Moving _______________________________________________________________ 36
Installation_________________________________________________________________________ 37

Hinge Adjustment ______________________________________________________________ 38
Kickplate Installation ____________________________________________________________ 40
Door Stop Adjustment __________________________________________________________ 41
Water Filter Installation __________________________________________________________ 42
System Specifications and Data___________________________________________________ 43
Final Installation ________________________________________________________________ 44

Performance Checklist ______________________________________________________________ 45
Control Panels _____________________________________________________________________ 46
Service & Registration_______________________________________________________________ 47

Содержание Side-By-Side & Bottom-Mount Refrigerator/Freezer

Страница 1: ... Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20414C 091207J Viking Installation Guide Side By Side Bottom Mount Refrigerator Freezer UL C UL ...

Страница 2: ...fessional Integrated Side by Side Dimensions Specifications Professional 42 48 ________________________________ 4 Dimensions Specifications Professional Integrated 42 48 _______________________6 Cutout Dimensions 42 __________________________________________________________ 8 Anti Tip Dimensions 42 _________________________________________________________ 9 Cutout Dimensions 48 ___________________...

Страница 3: ...inimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 425 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 243 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 652 lbs 293 4 kg 676 lbs 304 2 kg 48 Professional Side By Side Description VCSB483 VCSB483D Overall width 48 121 9 cm...

Страница 4: ...tubing inlet waterline requirements minimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 411 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 244 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 625 lbs 293 4 kg 676 lbs 304 2 kg 48 Professional Integrated Side By Side Descri...

Страница 5: ...f anti tip board 35 88 9 cm 3 1 2 8 9 cm 3 7 6 cm 35 88 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Professional Side By Side 9 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 41 1 2 105 4 cm min to 41 3 4 106 0 cm min 42 106 7 cm Professional Integrated models only 24 61 0 cm Electric Outlet Location Water Line En...

Страница 6: ...d 41 104 1 cm 3 1 2 8 9 cm 3 7 6 cm 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Professional Side By Side 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 47 1 2 120 7 cm min to 47 3 4 121 2 cm max 48 121 9 cm Professional Integrated models only 24 61 0 cm Electric Outlet Location Water Line Entry Area 6...

Страница 7: ...Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 9 amps Inlet water 1 4 copper tubing inlet waterline minimum 20 psi requirements maximum 120 psi Overall interior dimensions Refrigerator 15 2 cu ft 431 Liters Freezer 5 1 cu ft 145 Liters Total capacity 20 3 cu ft 576 Liters Approximate shipping weight 565 lbs 254 3 kg 36 Professional Integr...

Страница 8: ...oard 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Professional Bottom Mount 15 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 35 1 2 90 2 cm min to 35 3 4 90 8 cm max 36 91 5 cm Professional Integrated model only 24 61 0 cm Electric Outlet Location Water Line Entry Are...

Страница 9: ... cm Space if 24 standard cabinet depth is used Door 24 61 0 cm Standard Cabinet Depth Wall 3 4 1 9 cm Full End Panel 2 1 2 6 4 cm Offset Partial Overlay Cabinet Door Cabinet Information Professional 16 Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the ro...

Страница 10: ... 4 62 9 cm Wall 3 4 1 9 cm Full End Panel 3 4 1 9 cm If standard 25 63 5 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm If standard 25 63 5 cm standard cabinet depth is used Flush 25 63 5 cm Cabinet Depth Cabinet Door Cabinet Information Professional Integrated 18 Professional Integrated models fit flush in standard 24 61 0 cm deep cabinet opening...

Страница 11: ... Requirements minimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 425 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 243 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 642 lbs 289 kg 665 lbs 299 3 kg 48 Designer Side By Side Description DDSB483 DDSB483D Overall width 48...

Страница 12: ...anti tip board 35 88 9 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Side By Side 23 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 42 106 7 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 42 106 7 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 4 27...

Страница 13: ...ti tip board 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Side By Side 25 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 48 121 9 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 47 1 2 120 7 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 4...

Страница 14: ...om rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of handle 26 66 0 cm Cutout width 36 91 5 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 9 amps Inlet water 1 4 copper tub...

Страница 15: ...om of anti tip board 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Bottom Mount 29 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 36 91 5 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 36 91 5 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 ...

Страница 16: ...1 0 cm Standard Cabinet Depth 24 3 4 62 9 cm Wall 3 4 1 9 cm Full End Panel 3 4 1 9 cm If standard 25 63 5 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm If standard 25 63 5 cm standard cabinet depth is used Flush 25 63 5 cm Cabinet Depth Cabinet Door Cabinet Information Designer 30 Designer models fit flush in standard 24 61 0 cm deep cabinet ope...

Страница 17: ...Integrated 33 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 61 0 cm 6 15 2 cm Optional kickplate Notch dimensions determined by cabinets 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 6 15 2 cm 22 1 4 61 0 cm Custom Side Panel Dimensions Professional 32 Depending on how high leveling feet are raised an...

Страница 18: ...ounted 2X4s included bolted to two wall studs The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction Remove anything attached to rear or side walls that can obstruct unit installation Cutout dimensions are accurate Electrical outlet is in correct location Water line is in correct location Do not install a refrigeration unit near a heat source nor in a location where the surrounding...

Страница 19: ...R HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or more people to move and install appliance Failure to do so can result in death or serious injury Unpacking Unit 1 Remove top and bottom strap 2 Remove top cap 3 Cut carton rear approximately 1 4 0 6 cm to 1 2 5 ...

Страница 20: ...OTE DO NOT use plastic water lines 12 13 Flush water line by running two quarts of water into a bucket Turn water off Connect supply tube to water valve using a 1 2 wrench NOTE DO NOT overtighten 38 Remove four side screws and remove unit top Loosen the four hinge screws Adjust door Retighten four hinge screws Replace unit top Replace four side screws Attach one 2x4 to wall stud refer to dimension...

Страница 21: ...or 120 position 40 Turn on water supply and check for leaks Lift unit off rollers to desired height and level unit using a 5 16 head wrench NOTE DO NOT use an electric device Overtightening can cause damage Attach positive secure self tapping bolts to 2x4 using a 22 extension Verify that drain pan is installed and aligned Align holes on both ends of louvered panels and insert screws Using a Philli...

Страница 22: ...ation instructions parts and service availability and standard warranty are included with the product when shipped This drinking water system must be maintained according to manufacturer s instruction including replacement of filter cartridges Standard No 42 Aesthetic Effects Parameter USEPA Influent Influent Effluent Reduction Min Req McL Average Challenge Average Maximum Average Minimum Reductio...

Страница 23: ...Install anti tip device s and verify unit is secure h Position unit in cutout level at desired height and secure unit h Plug in unit and verify operation h Connect water supply if applicable Verify icemaker fill tube is properly inserted Verify icemaker bail arm is down Verify dispenser operation if applicable h Align square door s h Verify drain pan is properly installed and no leaks on water con...

Страница 24: ...ions Only authorized replacement parts may be used in performing service on the appliance Do not repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Record the following information indicated below You will need it if service is ever required The serial number and model number for your appliance ...

Отзывы: