background image

19

18

4

Feed supply cord up through hole in bottom

of range back.

1

2

5

1

2

6

Attach ground wire (green)

with ground screw that was removed.

Attach line #1 (black) and line #2 (red)

leads to outside terminal. Attach neutral wire (white)

to center terminal on terminal block.

1

3

7

1

2

8

Push supply cord toward terminal

block to relieve strain, reattach supply cord strain

relief bracket over supply cord.

Reattach access door.

1

2

Measure the four corners in cutout area to

verify if flooring is level.

For uneven or sloped floors, level unit with

metal shims only, as the adjustment required may

exceed the thread available in the leg.

3

3/

8”

3/8”

(0.

95

cm

)

(0.95 cm)

3/

8”

(0.

95

cm

)

4

Move unit into opening.

Leveling/Adjustments/Alignment

5

Check that unit is level side to

side and front to back. Side trim of the high corner

must be 3/8” (0.95 cm) above countertop.

If leveling is required, move unit out of opening.

6

1

2

1

Lift unit and prop on wood blocks.

1

1

Eyelet Connection

Bare Wire Connection

To make a bare wire connection, use holes on the left

side of the terminal block. To connect eyelet style

wires, use holes on right side of terminal.

Electrical Connection (4-wire)

(cont.)

Содержание RDSCE2305BSS

Страница 1: ...Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Website at vikingrange com F20942 EN 041012 UL C UL Freestanding 30 Electric Range ...

Страница 2: ...__________________________________________23 Final Preparation ___________________________________________________________________24 Performance Checklist ______________________________________________________________24 Service Registration_______________________________________________________________25 Before beginning please read these instructions completely and carefully Do not remove permane...

Страница 3: ...y any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below If the use of a GFI is required it should be Of the receptacle type breaker type or portable type NOT recommended Used with permanent wiring only temporary or portable wiring NOT recommended On a dedicated circuit no other receptacles switches or loads in the circuit Connected to a stan...

Страница 4: ...l oven capacity 4 7 cu ft Measure to AHAM standards 4 1 cu ft Approximate shipping weight 426 lbs 193 2 kg 29 7 8 75 9 cm 35 7 8 91 1 cm min to 37 94 0 cm max 6 15 2 cm Note Clearances from non combustible materials are not part of the ANSI Z21 1 scope and not certified by CSA Clearances to non combustible materials must be approved by the authority having jurisdiction Minimum clearances from adja...

Страница 5: ... and efficient operation of the hood 66 min 167 6 cm to 72 max 182 9 cm 66 min 167 6 cm to 72 max 182 9 cm 24 61 0 cm or 27 38 6 cm 30 76 2 cm 6 15 2 cm Wood Composite Overlay Wood Composite Overlay 30 min 76 2 cm to 36 max 91 4 cm 0 0 cm 30 min 76 2 cm to 36 max 91 4 cm Wall Installation Island Installation Note This range ships standard with a backguard Minimum clearance for back wall is 0 with ...

Страница 6: ...e location of a receptacle with respect to any significant sources of water or moisture Electric access area 6 15 2 cm 6 15 2 cm 4 3 8 4 3 8 11 1 cm 11 1 cm 4 3 8 11 1 cm 3 1 2 8 9 cm 3 7 6 cm REAR VIEW SIDE VIEW WARNING Electrical shock hazard To avoid the risk of electrical shock personal injury or death verify electrical power is turned off at the breaker box until the range is installed and re...

Страница 7: ...ts The vents need to be unobstructed and open to provide proper airflow for optimal oven performance CAUTION The cooling fan should be operating when the unit is in operation If you notice the cooling fan is not operating or you observe unusual or excessive noise coming from the cooling fan contact a Viking Authorized Service Center before continuing operation Failure to do so can result in damage...

Страница 8: ...rounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical shock hazard To avoid risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical...

Страница 9: ...cal shock personal injury or death grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical shock hazard To avoid risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence o...

Страница 10: ...ing is level For uneven or sloped floors level unit with metal shims only as the adjustment required may exceed the thread available in the leg 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 4 Move unit into opening Leveling Adjustments Alignment 5 Check that unit is level side to side and front to back Side trim of the high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out ...

Страница 11: ...on WARNING TIPPING HAZARD THIS RANGE CAN TIP A CHILD OR ADULT CAN TIP THE RANGE AND BE KILLED FAILURE TO INSTALL THE ANTI TIP DEVICE CAN RESULT IN DEATH OR SERIOUS BURNS TO CHILDREN OR ADULTS IF THE RANGE IS MOVED THEN THE ANTI TIP DEVICE MUST BE RE ENGAGED WARNING TIPPING HAZARD To reduce the risk of the appliance tipping it must be secured by a properly installed anti tip bracket s To make sure ...

Страница 12: ...it is not level repeat steps 5 7 of Leveling Adjustments Alignment section 1 1 2 2 3 2 Reattach door to range Open door completely Reattach hinge trim 3 4 Remove pins from hole in hinges Close door 5 If the door needs to be adjusted loosen hinge trim screws see step 2 Adjust the screws located between the door and kickplate using a 5 32 hex head allen wrench After adjustment tighten hinge trim scr...

Страница 13: ...atula or any other material tool to scrape stainless steel Scratches are almost impossible to remove NOTICE When conducting performance test DO NOT run self clean cycle for more than 10 minutes with oven racks inside oven This could cause them to discolor due to the high temperature required for self cleaning Only authorized replacement parts may be used in performing service on the appliance All ...

Страница 14: ...27 26 ...

Отзывы: