Attach line #1 (black) and line #2 (red)
leads to outside terminal. Attach neutral wire (white)
to center terminal on the terminal block.
1
1
Eyelet Connection
Bare Wire Connection
To make a bare wire connection, use holes on the left
side of the terminal block. To connect eyelet style
wires, use holes on right side of terminal.
Push supply cord toward terminal
block to relieve strain, reattach supply cord strain
relief bracket over supply cord.
1
2
6
Reattach access door.
2
1
1
3
2
1
2
Remove access door.
Remove supply cord strain relief
bracket and three supply cord mounting screws
on the terminal block.
Electrical Connection (4-wire)
WARNING
Electrical shock hazard.
To avoid risk or electrical
shock, personal injury or death;
grounding product to the frame
of the unit may or may not be permitted
through your local codes. If ground to the
frame is not permitted then a 4 conductor
power cord must be used.
WARNING
Electrical shock hazard.
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been
properly grounded in accordance with
local codes or in absence of codes, with
the National Electrical Code (NEC).
ANSI/NFPA 70-latest edition.
2
1
3
Remove grounding screw. Cut-off
and discard ground strap.
See Electrical Requirements information.
Where local codes do not permit grounding
through neutral, use a 4-wire power supply
cord. The cord or conduit must be secured
to the range with the strain relief bracket.
The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.
Electrical Connection (3-wire)
(cont.)