Note:
The
RAD-AMP
is factory configured
as a “Line Extender” . To change the mode
of operation or operating parameters, see
the “Programming” section and follow the
specific programming section for the
desired mode (Line Extender, Call
Diverter or Telecommuting Extender ).
LINE OUT
USE ONLY LISTED
CLASS 2 POWER
SOURCE 12V DC
500mA MAXIMUM
LINE IN
REMOTE
SWITCH
Center Pair
(Red & Green)
Rear View of the RAD-AMP
Open = OFF
Closed = ON
Optional Night Mode
Remote Switch
Incoming C.O. Line
or Analog PABX/KSU
Extension
Outgoing Second
C.O. Line or Analog
PABX/KSU Extension
120V AC/13.8V AC
Adapter
(included)
Note:
The front panel
ON/OFF
switch must be placed in the
OFF
position to utilize this feature.
Connect the incoming phone line to the
LINE IN
jack on
the back panel of the
RAD-AMP
. Connect a second
phone line or 600 ohm audio device to the
LINE OUT
jack. For normal operation, the front panel switch
should be set to the ON position and the remote night
switch contacts must be open.
D
D
e
e
f
f
i
i
n
n
i
i
t
t
i
i
o
o
n
n
s
s
Line Extender:
The mode of operation in which the
RAD-AMP
provides remote access to an analog station of a PABX,
KSU or a second C.O. line. This is ideal for bridging long distance areas or allowing remote employees to use company
lines for toll calls.
Call Diverter:
The mode of operation in which the
RAD-AMP
forwards a call to a pre-programmed phone number.
Telecommuting Extender:
The mode of operation in which the
RAD-AMP
forwards calls to one of nine pre-programmed
numbers as well as providing remote access to an analog PABX/KSU station or C.O. line, including all features available
to that station or C.O. line.
Security Code:
The code programmed into the
RAD-AMP
that allows access to all programming features.
Priority 1 Access Code:
The code programmed into the
RAD-AMP
that allows a remote user to have complete access
to the PABX or KSU including outside toll calls.
“Priority 2” Access Code:
The code programmed into the
RAD-AMP
that allows a remote user to have limited access to
the PABX or KSU, effectively blocking outside line access.
To utilize the Telecommuting extender mode for remote employees, the
RAD-AMP
must be installed as shown below
and DIP switches 3 and 4 must be set as shown before programming the unit.
12
ON
34
34
OFF ON
LINE OUT
USE ONLY LISTED
CLASS 2 POWER
SOURCE 12V DC
500mA MAXIMUM
LINE IN
REMOTE
SWITCH
Dials Out to Remote
Employee
Remote Employee's
Analog PABX/KSU
PABX/KSU
120V AC/13.8V AC
Adapter (included)
Remote
Employee
Rear View of the RAD-AMP
Internal View of the RAD-AMP
A. Line Extender/Call Diverter Installation
B. Telecommuting Extender Installation
2