Viking K-1275 Series Скачать руководство пользователя страница 5

Applications

Important:

To operate the

K-1275

during a power failure, a UPS should be installed.

A.  Connecting a Doorstrike to the K-1275 Internal Relay 

The 

K-1275

provides a dry contact output that can be used for operation of a door strike. To use this feature, the

Door Strike Code and Door Strike Time must be set in programming. In this mode, when the Door Strike Code is
detected, the 

K-1275

will energize the relay for the period of time selected in the Door Strike Time (see

Programming

section 

E, G

and 

H

). 

If a Postal Lock is required, connect the normally open contacts of the lock to the two white wires coming from the
two pin connector on the lower portion of the control board. When the postal lock is momentarily actuated, the
door strike will energize for the programmed Door Strike Time.

* Note:

To prevent unwanted radio interference, route the connecting wires through the included ferrite core.

** Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire

with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating.

E.  Wiring the K-1275 Proximity Card Reader

Back View of
 the K-1275

- Black (GND)

+ Red (5-14VDC)

Green (Date 0)

White (Data 1)

* Up to 500 ft

3-Wire Gel-Filled Butt 

Connectors included

(3M Scotchlok UR2)

24 Awg Stranded 

Shielded Cable

(Belden 9537)

Black

Red

Green

White

Black

Red

Green

White

To Viking model 

ES-1 or 

Equivalent 26-Bit 

Wiegand Card 

Reader Controller

Viking Model ES-1 (not included,

see DOD# 193 for more information)

VIKING

©

VIKING

ELECTRONICS

HUDSON, WI 54016

STAND ALONE 

DOOR CONTROLLER

ENTRY SYSTEM

POWER 12V DC

MODEL ES-1

1

POWER

PROGRAM

PHONE

LOG

BUS

2

3 4

5

GANG

PROG

6

7

8

9

WI

E

GAND

DEVICE

10 11

DOOR

STRIKE 

N.O. 

COM 

N.C.

BLK 

RED 

GRN

WHT

Doorstrike

12V DC 
Adapter

(included

with ES-1)

OR

Share power with 

12-24V AC/DC door 

strike with 200mA 

available current or use 

the included 12V DC 

adapter.

Touch Tone

Programming Phone

(not included)

Remote Touch Tone

Programming Phone

(not included)

OR

RAD-1A Remote Access

Device (not included,

see DOD# 410)

Doorstrike

Power Supply

12-24V AC or DC

xxxxxxx

VIKING

Model: 

Complies with FCC Part 15 & 68

V

iking Electronics, Inc. (715)386-8861

1531 Industrial St., Hudson, WI 54016

P/N: 

xxxxxxx

DEV

S/N: 

xxxxxxxx

RoHS

xxxxxxxxxxxxxx

Reg. No: 

REN: 

xxxx

www

.vikingelectronics.com  DOD# xxx

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from

both the AC outlet and the telephone line.  It is recommended that a surge protector be installed to protect
against such surges.

5

Rear View
of the K-1275

CO Line

Yellow (N.O.)

Brown (COM)

Green

Red

** Gel-Filled Butt Connectors (included)

Black

Black

* Ferrite Core

(included)

White

White

Postal Lock

Switch (N.O.)

Orange (N.C.)

120V AC

 Doorstrike / Magnetic Lock

120V AC

xxxxxxx

VIK

ING

Model: 

Complies with FCC Part 15 & 68

V

iking Electronics, Inc. (715)386-8861

1531 Industrial St., Hudson, WI 54016

P/N: 

xxxxxxx

DEV

S/N: 

xxxxxxxx

RoHS

xxxxxxxxxxxxxx

Reg. No: 

REN: 

xxxx

www

.vikingelectronics.com  DOD# xxx

Содержание K-1275 Series

Страница 1: ...s Marine grade 316 stainless steel faceplate and screws Internally sealed keypad Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection...

Страница 2: ...ustments Features Overview Keypad Push to initiate call push again to disconnect Zinc Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots t...

Страница 3: ...as a surface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts ar...

Страница 4: ...1275 120V AC Camera GND Camera Power 12V DC Adapter included 4 Crimp on Splice Connectors not included Video GND xxxxxxx VIKING Model Complies with FCC Part 15 68 Viking Electronics Inc 715 386 8861 1...

Страница 5: ...1 or Equivalent 26 Bit Wiegand Card Reader Controller Viking Model ES 1 not included see DOD 193 for more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTE...

Страница 6: ...N 1 2 3 COM N O N C AUX CONTACT OUTPUT 13 8V AC Adapter included Talk Battery Switch OFF ON CO line or Analog PABX KSU Station Earth Ground 5A 30V DC 250V AC maximum Red Green ON 1 2 3 DIP Switches Mo...

Страница 7: ...t 2 K 1270 Entry Point 1 Local Programming Phone 13 8V AC Adapter Included 120V AC Optional Push to Open Request to Exit Button available for each entry point not included N O COM N C DOOR STRIKE 1 VI...

Страница 8: ...ng programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call...

Страница 9: ...to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed d...

Страница 10: ...ration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON...

Страница 11: ...ss code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indi...

Страница 12: ...tance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version y...

Отзывы: