Viking K-1275 Series Скачать руководство пользователя страница 3

Installation

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC

outlet and the telephone line.  It is recommended that a surge protector be installed to protect against such surges. 

A.  Mounting

VIKING

©

1

2

3

4

5

6

7

8

9

0
  

#

*

#

*

   

0

9

8

7

6

5

4

3

2

1

Optional VE-5x10 Surface Mount 

Box (not included), see DOD# 424

10.0"

9.5"

4.50"

2.596"

5.00"

8.65"

0.425"

0.952"

Front View

of the K-1275-IP

9.12"

2.5"

4.5"

Zinc-Plated Steel

Rough-In Box

(included)

Side View

of the K-1275-IP

(8) #6-32 x 3/4" Stainless 

Steel, T-10 Torx Security 

Screws with drive bit                                                                                                             

(included)

14 Gauge Marine 

Grade 316 Stainless 

Steel Faceplate

10.14"

3.69"

5.22"

- OR -

B.  Changing the Directory

Paper Directory

Directory
Lens

  

C.  Wiring

Color

Function

Black

Power In 

Black

Power In 

Green

Phone Line In

Red

Phone Line In

Brown

Door Strike Relay common

Orange

Door Strike Relay NC

Yellow

Door Strike Relay NO

Blue

Camera Relay common

Violet

Camera Relay NC

White

Camera Relay NO

The 

K-1275

is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor

applications use the 

K-1275-EWP

. The 

K-1275

can either be installed as a flush mount unit using the included

rough in box, or as a surface mount unit using an optional 

VE-5x10

. The rough in box uses the inner set of four

holes on the face plate while the 

VE-5x10

uses the outside set of holes. A set of dummy screws and nuts are

provided to fill the unused mounting holes.

To install a directory, remove the four screws that mount
the directory lens to the front of the 

K-1275 

using the

included Allen wrench. Insert a paper directory behind the
lens and secure the two back onto the front panel being
careful to align the names with the front panel graphics.
For your convenience, the back of this document has pre-
printed directory forms.

Note: 

To print directory forms for the 

K-1275

, go to

www.vikingelectronics.com and enter “930” in the DOD
field at the top of the page for a direct link to the PDF.

The

K-1275

can be powered from any source supplying 12

to 24 volts, AC or DC. A 12 volt DC adapter is supplied with
the product. When using the included adapter, the plug on
the adapter cord will have to be removed. The power
connections to the 

K-1275

(black wires) are not polarity

sensitive.

There are also 8 more wires connected to the 

K-1275

controller board. Two wires are for the incoming phone line,
three are from the high current door strike relay and the last
three are from the camera relay. Gel filled butt connectors
are provided for easier connection to building wiring. The
table at the right describes each wire’s function.

3

Содержание K-1275 Series

Страница 1: ...s Marine grade 316 stainless steel faceplate and screws Internally sealed keypad Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection...

Страница 2: ...ustments Features Overview Keypad Push to initiate call push again to disconnect Zinc Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots t...

Страница 3: ...as a surface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts ar...

Страница 4: ...1275 120V AC Camera GND Camera Power 12V DC Adapter included 4 Crimp on Splice Connectors not included Video GND xxxxxxx VIKING Model Complies with FCC Part 15 68 Viking Electronics Inc 715 386 8861 1...

Страница 5: ...1 or Equivalent 26 Bit Wiegand Card Reader Controller Viking Model ES 1 not included see DOD 193 for more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTE...

Страница 6: ...N 1 2 3 COM N O N C AUX CONTACT OUTPUT 13 8V AC Adapter included Talk Battery Switch OFF ON CO line or Analog PABX KSU Station Earth Ground 5A 30V DC 250V AC maximum Red Green ON 1 2 3 DIP Switches Mo...

Страница 7: ...t 2 K 1270 Entry Point 1 Local Programming Phone 13 8V AC Adapter Included 120V AC Optional Push to Open Request to Exit Button available for each entry point not included N O COM N C DOOR STRIKE 1 VI...

Страница 8: ...ng programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call...

Страница 9: ...to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed d...

Страница 10: ...ration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON...

Страница 11: ...ss code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indi...

Страница 12: ...tance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version y...

Отзывы: