Viking K-1275 Series Скачать руководство пользователя страница 10

10

This timer sets the maximum amount of time the 

K-1275

will look for the call to be answered. If this timer expires

and the tenant has not answered, the call will be terminated or the 

K-1275

will dial a second phone number (if

programmed). The factory setting is 20 seconds, and to disable this feature, enter “

00

” into position 43.

J.  Maximum Ring Time

This time out is started once the call has been connected and is reset every time audio is detected on the phone
line. If it expires, the call will be terminated. This is useful on systems that are silent when the tenant hangs up to
assure the 

K-1275

disconnects. It is factory set to 10 seconds and can be disabled by entering “

00

” in position

44.

K.  Silence Time Out

This time represents the amount of time the 

K-1275

will delay before switching back to the microphone mode

after it was in the speaker mode (VOX switching time). It is in 100 msec increments and stored in position 45.

L.  Talk/Listen Delay

On some phone lines, a faster rate of dialing is allowed. The dialing speed of the 

K-1275

can be altered to take

advantage of this faster rate. The normal dialing speed is 5 digits per second and is selected by entering “

#30

(factory setting) while in programming. To increase the speed to 10 digits per second, enter “

#31

”. If the faster

rate is selected, be sure to test each number to assure proper operation.

M.  Dialing Speed

The 

K-1275

is factory set to hang up if continuous audio is detected after dialing. In most situations this would

happen if the tenant hung up and the service that the 

K-1275

is connected to provides a dial tone following the

hang up. In some instances due to noisy lines or loud background noise, the call may be terminated before the
tenant hangs up. If this occurs, enter “

#33

” when in programming. This will disable return to dial tone feature and

stop the 

K-1275

from hanging up prematurely. To enable this feature enter “

#32

” when in programming.

N.  Hang Up on Return to Dial Tone

See Operation for a functional description of this feature.  Tenant Initiated Entry is disabled by default.  To enable
it, enter programming (see 

Programming

section 

A

).  Enter

#38

.  Also, DIP switch 1 must be turned ON and left

in this position to enable the 

K-1275

to answer incoming calls.  To disable Tenant Initiated Entry, enter 

#37

.

Security considerations with Tenant Initiated Entry:

The 

K-1275

door entry system is designed with security

in mind, which is the reason an access code is recommended in cases where Tenant Initiated Entry is allowed.
To understand the need for an access code, consider the following example.  A person walks up to the entry and
pushes one of the directory buttons on the 

K-1275

.  The unit looks up the number associated with that directory

position and dials it.  The phone inside the tenant’s apartment rings, and is answered by someone who happens
to be a guest in the tenant’s apartment.  The guest notices that the tenant’s phone is displaying the caller ID of
the number that just called, which is the number of the 

K-1275

.  They jot the number down.  The guest can now

call the 

K-1275

at a later time, if DIP switch 1 is on, Tenant Initiated Entry is allowed, the access code is disabled,

and they know the door strike code, they can let themselves into the building.  Note that by default, Tenant Initiated
Entry is not allowed, but if this feature is allowed, it is important to program an access code (see 

C.  Access Code

(

memory location #48

).

O.  Tenant Initiated Entry

To clear all speed dial positions and set all modes back to factory setting, enter “

###

“ while in programming.

Caution

, all previous programming will be lost

. Normally when the 

K-1275

is in the programming mode, it will

hang up the line if no commands are detected for 20 seconds. To hang up immediately, enter “

##7

”.

P.  Special Commands

In some installations, it maybe desirable to limit the length of the call to the tenant. This can be done by
programming position 

#42

. The maximum call time can be set from 1 minute to 9 minutes by entering the

appropriate number in position 

#42

.  A “

0

” will yield a 30 second time. To disable the call timer enter “

#42

” without

any preceding digit.

I.   Maximum Call Time

Содержание K-1275 Series

Страница 1: ...s Marine grade 316 stainless steel faceplate and screws Internally sealed keypad Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection...

Страница 2: ...ustments Features Overview Keypad Push to initiate call push again to disconnect Zinc Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots t...

Страница 3: ...as a surface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts ar...

Страница 4: ...1275 120V AC Camera GND Camera Power 12V DC Adapter included 4 Crimp on Splice Connectors not included Video GND xxxxxxx VIKING Model Complies with FCC Part 15 68 Viking Electronics Inc 715 386 8861 1...

Страница 5: ...1 or Equivalent 26 Bit Wiegand Card Reader Controller Viking Model ES 1 not included see DOD 193 for more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTE...

Страница 6: ...N 1 2 3 COM N O N C AUX CONTACT OUTPUT 13 8V AC Adapter included Talk Battery Switch OFF ON CO line or Analog PABX KSU Station Earth Ground 5A 30V DC 250V AC maximum Red Green ON 1 2 3 DIP Switches Mo...

Страница 7: ...t 2 K 1270 Entry Point 1 Local Programming Phone 13 8V AC Adapter Included 120V AC Optional Push to Open Request to Exit Button available for each entry point not included N O COM N C DOOR STRIKE 1 VI...

Страница 8: ...ng programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call...

Страница 9: ...to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed d...

Страница 10: ...ration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON...

Страница 11: ...ss code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indi...

Страница 12: ...tance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version y...

Отзывы: