Viking K-1205-IP Series Скачать руководство пользователя страница 4

4

Features Overview

MAC:

18E80FXXXXXX

asdesaxtff

N.C.

 - Black

+ Red

 Green

 Green

N.O.

COM.

N.C. (Gray)

N.O. (Yellow)

COM. (Blue)

 Relay 1

Output Contacts

(2A@30VDC/ 250VAC max)

 Relay  2 Output Contacts

(2A@30VDC/ 250VAC max)

 Request for Exit 

(REX) Input

* 3 Gel-Filled Butt

Connectors 

(included)

+ Red

- Black

Black

Black

- Black

+ Red

Speaker

LED

Microphone

Call Switch

MAC Address Label: 

The 

MAC address is a unique 
12 digit number used by 
routers to send network 
traffic to the correct IP 
address.

PoE LAN Port 10/100, 
PoE Class 2 (<6.5 Watts): 

Connect to your LAN via 
RJ45 plug and CAT5 or 
greater twisted pair wire.

Yellow Network Status 
LED: 

Lights steady to 

indicate power and data 
link. Blinks to indicate 
network activity.

Green Unit Status LED

Rear (PCB) View of the

K-1205-IP Entry Phone

White

White

(Power typically not

required for gate controllers)

Doorstrike / 
Magnetic Lock

120V AC

Connect to Optional 

Doorstrike, Mag Lock, 

Gate Controller, etc.

(not

connected)

12 VDC Power Output for 

VE-LIGHT, etc. 

(12VDC @ 50mA max)

  

Brown

Violet

White

 - Black

+ Red

 Green

 White

Model PRX-1 

Proximity Card 

Reader DOD 221

Model PRX-3 

Medium 

Range Proximity Card 
Reader DOD 228

Camera 

Power  

 - Black

+ Red

26 Bit Wiegand Input / Output

For connecting optional Proximity Card Readers, 
see Viking models above (not included) or program 
as a output to connect to the card reader input of an 
Access Control System

Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. 

Keypad:

  Push to initiate call, push again to 

disconnect. Zinc Die cast with Satin Chrome 
Finish, internally sealed per IP67.

Speaker Screen:

  Speaker screen with 0.018" 

wide slots to prevent punctures from paperclips, 
etc.

Faceplate Material:

  14 gauge 316 stainless steel 

with #4 brushed finish.

Speaker:

  Mylar speaker with rubber gasket to 

maintain water-tight seal and eliminate water 
deterioration.

Blue Call LED:

  Lights steady when idle, flashes 

during dialing, then lights steady when answered.

Microphone:

  Omni-directional microphone with 

protective water-resistant cloth.

Front View of the

K-1205-IP Entry Phone

Condensation Drain Hole

Mounting Screws:

  

(4) 6-32 X 3/4” Marine grade 

316 stainless steel, flat head, T-10 Torx security 
screws and drive bit (included).

Laser Etched Graphics: 

For long lasting easy to 

read graphics. 

VIKING

©

1

2

3

4

5

6

7

8

9

0
  

#

*

#

*

  

  

0

9

8

7

6

5

4

3

2

1

1

2

3

4

5

6

7

8

9

0

#

*

Color Video Camera:

  Wide operating 

temperature range of -40°F to 140°F, NTSC 
composite video output with 420 lines of 
resolution, 80° wide viewing angle lens, tilt and 
swivel adjustments for aiming towards visitors.

Protective Camera Window:

  Impact resistant 

polycarbonate lens with scratch resistant coating 
and water-tight gasket.

Содержание K-1205-IP Series

Страница 1: ...terproof scratch resistant lens and 12 buttons for single push auto dialing of a tenant s phone number or business extension When the K 1205 IP phone is connected to an apartment or business tenant a...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers to send network traffic to...

Страница 4: ...ded or program as a output to connect to the card reader input of an Access Control System Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire...

Страница 5: ...al St Hudson WI 54016 DEV RoHS J6 Q171570 8 2W J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a pass...

Страница 6: ...nt the directory lens to the front of the K 1205 IP using the included Allen wrench Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the nam...

Страница 7: ...TUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 7 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network IBM compatible personal computer...

Страница 8: ...you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the net...

Страница 9: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 10: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Страница 11: ...must be set to Door Strike 22 18 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 18 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit a...

Страница 12: ...field blank 1 Unit Name Up to a 31 character unit name can be assigned to the K 1205 IP Series Phone being programmed When registered to a SIP server in the event that registration is lost you can pro...

Страница 13: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1205 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...ty Card entries but also log any errors incorrect codes or non valid card reads Keyless Entry Code and Proximity Card logging can also be set to Live Logging With Live logging selected and the K 1205...

Страница 16: ...er is sent over the Weigand output along with the facility code selected Since Wiegand data limits the entry code to 65535 maximum plus entry codes higher than 65535 are not sent over the Wiegand outp...

Страница 17: ...r strike relay is activated After the called party enters the correct relay activation command the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound rel...

Страница 18: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Страница 19: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1205 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Страница 20: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Страница 21: ...ne of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Relay...

Страница 22: ...mber can be programmed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card...

Страница 23: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 24: ...The use of magnets to mount the VE Series enclosure to a metal surface can affect the operation of the enclosed product Caution Handsfree phones are not suitable for noisy applications see Important...

Страница 25: ...r strikes and gates when a remote relay is required for security reasons It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs Two RC 4...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: