Viking K-1205-IP Series Скачать руководство пользователя страница 12

12

Programming Features

3.  Peer to Peer Settings

When set to Peer to Peer mode, a SIP server is not used. The unit should be programmed with a Static IP Address and
Username, a password is not used. Caller ID can be programmed if needed. Simply call the unit by entering the
programmed “[email protected]...(Static IP address for the unit)”. The static IP address is normally programmed into
a page button on the VoIP telephones. 

4.  Outbound Proxy 

If your SIP provider requires an outbound proxy IP address enter it in the Outbnd Proxy field. If outbound proxy is not
required enter the SIP sever IP address into the Outbnd Proxy field.

Note: 

If not required, this field must match your

SIP server IP address.

5.  Authentication ID

If your SIP provider requires Authentication ID, enter it in the Authentic. ID field. If Authentication ID is not required,
leave this field blank.

1.  Unit Name

Up to a 31 character unit name can be assigned to the 

K-1205-IP Series 

Phone being programmed. 

When registered to a SIP server in the event that registration is lost you can program the unit to re-resolve using the
current SIP server IP address or route pages through an alternate SIP server. With Alternate Server selected enter the
IP address of the alternate SIP server in the field next to the Register Fails drop down box.  

Note: 

With an alternate

SIP server IP address programmed, the IP address for the SIP server and alternate SIP server will be limited to 31
characters.

6.  Register Fails (Re-Resolve or Alternate Server)

Enter the IP address or URL of your SIP server or service provider in this field. The SIP server IP address is limited to
74 characters.  

Note: 

If an alternate SIP server IP address is programmed, the IP address for the SIP server and

alternate SIP server will be limited to 31 characters. 

Note: 

If outbound proxy is not required, enter the SIP server IP

address into the Outbnd Proxy field.

2.  SIP Server

Содержание K-1205-IP Series

Страница 1: ...terproof scratch resistant lens and 12 buttons for single push auto dialing of a tenant s phone number or business extension When the K 1205 IP phone is connected to an apartment or business tenant a...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers to send network traffic to...

Страница 4: ...ded or program as a output to connect to the card reader input of an Access Control System Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire...

Страница 5: ...al St Hudson WI 54016 DEV RoHS J6 Q171570 8 2W J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a pass...

Страница 6: ...nt the directory lens to the front of the K 1205 IP using the included Allen wrench Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the nam...

Страница 7: ...TUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 7 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network IBM compatible personal computer...

Страница 8: ...you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the net...

Страница 9: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 10: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Страница 11: ...must be set to Door Strike 22 18 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 18 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit a...

Страница 12: ...field blank 1 Unit Name Up to a 31 character unit name can be assigned to the K 1205 IP Series Phone being programmed When registered to a SIP server in the event that registration is lost you can pro...

Страница 13: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1205 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...ty Card entries but also log any errors incorrect codes or non valid card reads Keyless Entry Code and Proximity Card logging can also be set to Live Logging With Live logging selected and the K 1205...

Страница 16: ...er is sent over the Weigand output along with the facility code selected Since Wiegand data limits the entry code to 65535 maximum plus entry codes higher than 65535 are not sent over the Wiegand outp...

Страница 17: ...r strike relay is activated After the called party enters the correct relay activation command the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound rel...

Страница 18: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Страница 19: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1205 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Страница 20: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Страница 21: ...ne of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Relay...

Страница 22: ...mber can be programmed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card...

Страница 23: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 24: ...The use of magnets to mount the VE Series enclosure to a metal surface can affect the operation of the enclosed product Caution Handsfree phones are not suitable for noisy applications see Important...

Страница 25: ...r strikes and gates when a remote relay is required for security reasons It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs Two RC 4...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: