30. Inbound Call Mode

The Inbound Call Mode determines how the 

K-1205-IP 

handles incoming SIP calls.  One option is to auto answer a

SIP call to transmit a page, control  the relay or listen to transmit audio from the microphone.  Another option is the
silent monitor mode, which allows callers to listen to the transmit audio from the microphone.  The “secure” options for
auto answer require the callers to dial the access code in order to transmit a page, activate the relay or activate the
optional 

RC-4A

relays. 

Factory Setting: 

Auto Answer

Disabled

:  In the “Disabled” mode the phone will not automatically answer an incoming call. 

Auto Answer:

In the “Auto Answer” mode the phone will automatically answer an incoming call on the first ring. 

Auto Answer Secure 

– Inbound calls are auto answered and the caller must dial the access code in order to listen or

talk on the unit.

Silent Monitor 

– Inbound calls are auto answered and the caller hears transmit audio from the microphone at a much

higher volume level.

Silent Monitor Secure 

– Inbound calls are auto answered and the caller must dial the access code in order to listen

to transmit audio from the microphone (volume level is still at a much higher volume level).

Note:

For Silent Monitor mode(s), the speaker can be enabled by dialing 9# from the connected phone. 

If enabled and a busy is detected, the 

K-1205-IP

phone will dial the “Roll Over” speed dial number.   

Factory Setting: 

Enabled

Note:

If the busy signal is interrupted with a promotional message, contact your central office to have it removed.

32.  Dial Next Number on Busy 

31. Dial Next number on Ring No Answer

If enabled and a ring-no-answer is detected, the 

K-1205-IP

phone will dial the “Roll Over” speed dial number after the

programmed amount of rings. A momentary press of the call button will dial the first programmed Speed Dial number.
This can be set from 1 - 9 rings.  

Factory Setting:

7 (will redial after 7 rings)

34. In Call Dialing Format

33. In Call Dialing

The In Call Dialing Format can be set to In-Band DTMF (Touch Tones) or RFC 2833 (Out of Band DTMF Touch Tones). In
Call dialing refers to the numbers dialed (from the 

K-1205-IP

’s keypad). after an outbound call has been answered by the

distant party. This would typically be the numbers dialed to steer through automated attendants, voice mail, etc. If your
VoIP phone system does not automatically convert out of band DTMF to In-Band after the call is answered, set In Call
Dialing Format to “Inband DTMF”.  

Factory Setting: 

RFC 2833

In Call Dialing refers to the numbers dialed (from the 

K-1205-IP

’s keypad) after an outbound call has been answered by

the distant party. This would typically be the numbers dialed to steer through automated attendants, voice mail, etc. 

Factory Setting: 

Disabled

Содержание K-1205-IP Series

Страница 1: ...terproof scratch resistant lens and 12 buttons for single push auto dialing of a tenant s phone number or business extension When the K 1205 IP phone is connected to an apartment or business tenant a...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers to send network traffic to...

Страница 4: ...ded or program as a output to connect to the card reader input of an Access Control System Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire...

Страница 5: ...al St Hudson WI 54016 DEV RoHS J6 Q171570 8 2W J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a pass...

Страница 6: ...nt the directory lens to the front of the K 1205 IP using the included Allen wrench Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the nam...

Страница 7: ...TUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 7 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network IBM compatible personal computer...

Страница 8: ...you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the net...

Страница 9: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Страница 10: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Страница 11: ...must be set to Door Strike 22 18 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 18 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit a...

Страница 12: ...field blank 1 Unit Name Up to a 31 character unit name can be assigned to the K 1205 IP Series Phone being programmed When registered to a SIP server in the event that registration is lost you can pro...

Страница 13: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1205 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Страница 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 15: ...ty Card entries but also log any errors incorrect codes or non valid card reads Keyless Entry Code and Proximity Card logging can also be set to Live Logging With Live logging selected and the K 1205...

Страница 16: ...er is sent over the Weigand output along with the facility code selected Since Wiegand data limits the entry code to 65535 maximum plus entry codes higher than 65535 are not sent over the Wiegand outp...

Страница 17: ...r strike relay is activated After the called party enters the correct relay activation command the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound rel...

Страница 18: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Страница 19: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1205 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Страница 20: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Страница 21: ...ne of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Relay...

Страница 22: ...mber can be programmed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card...

Страница 23: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 24: ...The use of magnets to mount the VE Series enclosure to a metal surface can affect the operation of the enclosed product Caution Handsfree phones are not suitable for noisy applications see Important...

Страница 25: ...r strikes and gates when a remote relay is required for security reasons It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs Two RC 4...

Страница 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: