background image

42

” m

in.

(10

6.7

cm

)

13

” m

ax

.

(

33

.0

cm

)

6”

min

.

(15.2

cm

)

18

” m

in.

(45

.7

cm

)

3/

8”

(0.

95

cm

)

36

(91

.4

cm

)

29-7

/8”

(75.9

cm

)

Clearance Dimensions

(Wood/Composite Overlay)

7

Clearance Dimensions

(Proximity to Cabinets)

6

• This range may be installed directly

adjacent to existing 36” (91.4 cm) high
base cabinets.

IMPORTANT:

The side trim MUST be

3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.

• The range CANNOT be installed

directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above 36”
(91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side
clearance from the range to such
combustible surfaces above the
36” (91.4 cm) counter height.

• Within the 6” (15.2 cm) side

clearance to combustible vertical
surfaces above 36” (91.4 cm), the
maximum wall cabinet depth
must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm)
side clearance must be 18”
(45.7 cm) above the 36”
(91.4 cm) high countertop.

• Wall cabinets above the range must be a

minimum of 42” (106.7 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.

The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information. These
dimensions provide for safe and efficient
operation of the hood.

66”

min

.

(167

.6 c

m)

to

72”

max

.

(182

.9 c

m)

66”

min

.

(167

.6 c

m)

to

72”

max

.

(182

.9 c

m)

24

(61

.0

cm

)

or

27

(38

.6

cm

)

30

(76

.2

cm

)

6”

(15

.2 c

m)

Woo

d/C

om

posit

e

Ove

rlay

Woo

d/C

om

posit

e

Ove

rlay

30”

min

.

(76.2

cm

)

to

36”

max

.

(91.4

cm

)

0”

(

0 c

m)

30”

min

.

(76.2

cm

)

to

36”

max

.

(91.4

cm

)

Wall Installation

Island Installation

Note:

Minimum clearance for back wall is 0” with

backguard or high-shelf.

Note:

If a range hood is installed, wall cabinets

above the range have a different minimum
clearance height.

Note:

6” (15.2 cm) min. with island trim and

combustible

rear wall. 0” with island trim

and

non-combustible

rear wall.

Note:

Minimum clearance for back wall

is 0” with backguard or high-shelf.

CAUTION

Burn hazard.

To avoid risk of personal injury;

the use of cabinets for storage

above the appliance may result

in a potential burn hazard. Combustible

items may ignite, metallic items may

become hot and cause burns. If a cabinet

storage is to be provided the risk can be

reduced by installing a rangehood that

projects horizontally a minimum 5” (12.7 cm)

beyond the bottom of cabinets.

Содержание F20508

Страница 1: ...eet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20508C EN 112508J Viking Installation Guide Profes...

Страница 2: ...ances must be observed Installation must conform with local codes Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appl...

Страница 3: ...0 watts 1 800 watts 800 watts 1 800 watts Oven interior width 25 5 16 64 6 cm Oven interior height 16 1 2 41 9 cm Oven interior depth AHAM 16 13 16 42 7 cm Overall 19 1 2 49 5 cm Oven volume Total ove...

Страница 4: ...the cooking surface The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 c...

Страница 5: ...ap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed and wiped dry Solutions stronger...

Страница 6: ...Leg Installation 10 WARNING DANGER CAUTION FOR YOUR SAFETY To avoid risk of personal injury or product damages DO NOT use the handle or oven door to lift the oven Remove door before installation to en...

Страница 7: ...ion is made at the terminal block which is located behind the access door on the back of the range 3 2 1 2 Remove supply cord strain relief bracket and three supply cord mounting screws on terminal bl...

Страница 8: ...unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical shock hazard To avoid risk of electrica...

Страница 9: ...el For uneven or sloped floors level unit with metal shims only as the adjustment required may exceed the thread available in the leg 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 4 Move unit into opening Lev...

Страница 10: ...ignment section 18 1 Note Refer to range electrical requirements section for proper installation information 1 2 4 Attach bracket with mounting hardware provided Connect electrical in shaded area See...

Страница 11: ...e they are on then abort self clean cycle to unlock door Final Preparation All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If b...

Страница 12: ...__ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Отзывы: