Viking E-32 Скачать руководство пользователя страница 5

5

C. Quick Programming Features

D. Speed Dial Numbers

The speed dial number programmed in location 

#00

is the telephone or extension number that is

dialed when the “

Call

” button is first pressed.  Additional speed dial numbers will be dialed when

there is no answer or a busy signal is detected and the next number redial features are activated.
The 

E-30/32

will cycle through the programmed speed dial numbers until answered.  To program,

enter the desired speed dial number followed by the memory location number (

#00 - #04

). 

To clear a speed dial location, simply enter the memory location (

#00 - #04

) alone.  The 

E-30/32

is factory set with no speed dial number programmed.

Note:

Up to 20 digits can be stored in each dial position.  Special features such as pause, mode change, touch tone 

Q

and 

#

count as single digits.

Description

Enter Digits

+

Memory Location

First speed dial number  

0-20 digits

then

#00

Second speed dial number  

0-20 digits

then

#01

Third speed dial number  

0-20 digits

then

#02

Fourth speed dial number  

0-20 digits

then

#03

Fifth speed dial number  

0-20 digits

then

#04

To add a 

Q

at any point in the dialing string

QQ

To add a 

#

at any point in the dialing string 

Q

#

To add a four second pause at any point in the dialing string

Q

7

Miscellaneous options (factory set to 000210) 

6 digits

then

#17

Timing/Dialing options (factory set to 234721) 

6 digits

then

#18

Security code (factory set to 845464) 

6 digits

then

#19

Exit programming and disconnect 

#7

Reset all programming to factory default settings  

###

To Program:

Enter:

Q

QQ

#

Q

#

4 second pause

Q

7

0, 1, 2 .... 9

0, 1, 2 .... 9

Setting B - Call Length Time Out

This feature selects the maximum length of time that calls can be connected.
Programmable in increments of 1 minute up to a maximum of 9 minutes (Touch
Tones 1 - 9). Program 0 in this location to disable the call length time out.  With the
call length disabled, the 

E-30/32

phone must rely on a CPC signal, busy signal,

silence or return to dial tone to hang-up.  Use chart at the right.

Note:

The factory default is 3 minutes.

E. Timing/Dialing Options

(memory location #18)

There are six positions in the timing/dialing options.  To program these options, enter the six desired timing/dialing
numbers followed by 

#18

.  The six available timing/dialing options are defined as follows:

Dial: A + B + C + D + E + F + # + 1 + 8

Factory Default Setting: 2 + 3 + 4 + 7 + 2 + 1

Talk/Listen Delay
Call Length
Silence Time Out
Dial Next Number on Ring No Answer
Dial Next Number on Busy
Future Use (set to 1)

Enter Timing/Dialing Settings Here:

A    B    C    D    E    F

#18

Setting A - Talk/Listen Delay

This feature selects switching time between talk and listen modes (VOX switching
time).  Use chart at the right.  * 

Note: 

The factory default is .2 seconds.

Touch Tone

Talk/Listen Delay

1

0.1 seconds

2

0.2 seconds*

3

0.3 seconds

4

0.4 seconds

5

0.5 seconds 

6

0.6 seconds

7

0.7 seconds

8

0.8 seconds

9

0.9 seconds

Touch Tone

Call Length Time Out

0

Disabled

1

1 minute

2

2 minutes

3

3 minutes*

4

4 minutes

5

5 minutes

6

6 minutes

7

7 minutes

8

8 minutes

9

9 minutes

Содержание E-32

Страница 1: ...25VAC RMS REN 0 5A Dimensions Overall 5 x 5 x 2 25 127mm x 127mm x 57mm Plastic Electrical Box 4 x 4 x 2 12 102mm x 102mm x 54mm Shipping Weight 2 2 lbs 1 Kg Operating Temperature 30 F to 150 F 34 C t...

Страница 2: ...Ground grounding rod water pipe etc Installation Optional VE 5x5 Surface Mount Box not included 2 25 Condensation Drain Hole 5 14 5 22 3 25 4 0 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 4...

Страница 3: ...aces brick stucco etc apply a bead of clear silicone caulking around the top edge and sides of faceplate For surface mount applications use model E 30 or E 30 EWP with a VE 5x5 surface mount box Dimen...

Страница 4: ...connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off bare wire ends prior to terminating Programming B Security Code memory locati...

Страница 5: ...5464 6 digits then 19 Exit programming and disconnect 7 Reset all programming to factory default settings To Program Enter Q QQ Q 4 second pause Q7 0 1 2 9 0 1 2 9 Setting B Call Length Time Out This...

Страница 6: ...ngs A B C Not Applicable F Miscellaneous Options memory location 17 Dial A B C D E F 1 7 Factory Default Setting 0 0 0 2 1 0 Not Applicable enter 0 Hang up on Return to Dial Tone Double Ring Cadence L...

Страница 7: ...ise Canceling ANC feature will allow speakerphone two way communications to continue to work properly even when subjected to loud noise such as a diesel engine or traffic Switch A Switch B Description...

Страница 8: ...plies with Part 68 of the FCC rules and the requirements adopted by theACTA Inside the front panel of this equipment is a label that contains among other information a product identifier in the format...

Отзывы: