Viking E-32 Скачать руководство пользователя страница 1

PRODUCT MANUAL

Designed, Manufactured and Supported in the USA

C O M M U N I C A T I O N   &   S E C U R I T Y   S O L U T I O N S

E-30 / E-30-EWP

E-32 / E-32-EWP

Handsfree Speaker

Phones with Dialers

December 13, 2018

VIKING

Features

Applications

Specifications

Provide Reliable and Intelligent

Handsfree Communication!

•  Automatic Noise Canceling (ANC) feature for clear audio - even in noisy

environments

•  

Vandal Resistant Features:

14 gauge louvered 316 brushed stainless steel

faceplate with permanent laser etched graphics, speaker/mic screen, heavy duty
metal “Call” button and T-10 Torx security mounting screws and drive bit

•  

Weather Resistant Features:

Marine grade 316 stainless steel faceplate, screws

and push button switch. Switch internally sealed per IP67. Mylar speaker. Self-
draining mic mount. Faceplate, mic and speaker gaskets. Weather resistant
powder paint on optional 

VE-5x5

(

DOD 424

).

•  Telephone line powered

•  Non-volatile memory (no batteries required)

•  Programmable to dial up to 5 numbers on busy / ring no answer

•  Blue off-hook LED indicator

•  Volume adjustments for microphone and speaker

•  Advanced call progress detection: disconnects on busy signal, return to dial tone,

CPC, reorder tone, maximum call time out and programmable silence time out

•  Selectable auto-answer feature for monitoring

•  Extended temperature range (-30°F to 150°F)

•  

E-30

Flush mounts using the included rough-in box or  surface mount using an

optional 

VE-5x5

surface mount box, sold separately (

DOD 424

)

•  

E-30-EWP

and 

E-32-EWP

are designed to meet IP66 Ingress Protection Rating

(see 

DOD 859

for more information)

•  

E-32

flush mounts in a standard double gang box (not included) 

•  Optional 

PB-1

Panic Button Kit (

DOD 233

)

•  Also available with VoIP interface, see 

DOD 248

for more information

Power: 

Telephone line powered. Minimum 24V DC talk battery voltage, with a

minimum loop current of 20mA loop. Loop current may be boosted on low current
lines with a Viking 

TBB-1B 

Talk Battery Booster (

DOD 632

).

Minimum Ring Voltage:  

25VAC RMS

REN #: 

0.5A

Dimensions:  

Overall:  5” x 5” x 2.25” (127mm x 127mm x 57mm)

Plastic Electrical Box:  4” x 4” x 2.12” (102mm x 102mm x 54mm)

Shipping Weight:

2.2 lbs (1 Kg)

Operating Temperature:  

-30°F to 15  0°F (-34°C to 65°C)

Humidity - E-30 / E-32:

5% to 95% non-condensing

Humidity - E-30-EWP / E-32-EWP:

Up to 100% condensing

Connections:  

Gel-filled butt connectors

The 

E-30 

and

E-32

handsfree phones are

designed to provide quick and reliable
handsfree communication and can be
connected directly to a C.O. line or analog
PABX/KSU station.

The 

E-30 

and

E-32

feature non-volatile

memory, built in dialers, and intelligent call
progress detection for automatic hang-up when
a call is completed. They can be programmed
to dial up to 5 different numbers on ring no
answer or busy and can be configured to dial
these numbers until answered.

Models 

E-30-EWP

and 

E-32-EWP 

add Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed

to precipitation or condensation.  EWP products feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as
well as urethane or thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy
on-site programming. For more information on Enhanced Weather Protection, see

DOD 859

.

E-30 / E-30-EWP

Flush mount with the

included rough-in box

E-30 shown with optional

VE-5x5 Surface Mount Box

(sold separately)

CAUTION - When installing on an analog extension of a phone system:  

Some phone systems do

not conform to analog telecom standards and might not be compatible with the 

E-30 

or

E-32

speaker

phones. For a detailed description of the telephone line specifications required for any of the 

E-30 

or

E-32

phones, see 

DOD 869

Note: 

Areas with loud background noise may require the push to talk version: 

E-30-PT

or 

E-30-PT-EWP

.

•  ATM machines
•  Convention centers

Non-ADA Hot-Line Phone for:

•  Elevators
•  Parking lots

•  Stadiums
•  Parking ramps

•  Residences
•  Businesses

Gate and Door Entry Phone for:

•  Building lobbies     
•  Pedestrian gates

•  Silent holdup alarm dialer 

using optional Viking PB-1

E-32 / E-32-EWP

Flush mount in a standard

double gang electrical box

(not included)

www.VikingElectronics.com

Содержание E-32

Страница 1: ...25VAC RMS REN 0 5A Dimensions Overall 5 x 5 x 2 25 127mm x 127mm x 57mm Plastic Electrical Box 4 x 4 x 2 12 102mm x 102mm x 54mm Shipping Weight 2 2 lbs 1 Kg Operating Temperature 30 F to 150 F 34 C t...

Страница 2: ...Ground grounding rod water pipe etc Installation Optional VE 5x5 Surface Mount Box not included 2 25 Condensation Drain Hole 5 14 5 22 3 25 4 0 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 4...

Страница 3: ...aces brick stucco etc apply a bead of clear silicone caulking around the top edge and sides of faceplate For surface mount applications use model E 30 or E 30 EWP with a VE 5x5 surface mount box Dimen...

Страница 4: ...connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off bare wire ends prior to terminating Programming B Security Code memory locati...

Страница 5: ...5464 6 digits then 19 Exit programming and disconnect 7 Reset all programming to factory default settings To Program Enter Q QQ Q 4 second pause Q7 0 1 2 9 0 1 2 9 Setting B Call Length Time Out This...

Страница 6: ...ngs A B C Not Applicable F Miscellaneous Options memory location 17 Dial A B C D E F 1 7 Factory Default Setting 0 0 0 2 1 0 Not Applicable enter 0 Hang up on Return to Dial Tone Double Ring Cadence L...

Страница 7: ...ise Canceling ANC feature will allow speakerphone two way communications to continue to work properly even when subjected to loud noise such as a diesel engine or traffic Switch A Switch B Description...

Страница 8: ...plies with Part 68 of the FCC rules and the requirements adopted by theACTA Inside the front panel of this equipment is a label that contains among other information a product identifier in the format...

Отзывы: