Service Diagnostics and Procedures 

© 2011 Viking Preferred Service 

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit 
before servicing. After servicing, reconnect electrical power and gas supply. Before placing appliance into 
operation, always check for gas leaks with soapy water solution. 

DO NOT

 

USE AN OPEN FLAME TO 

CHECK FOR GAS LEAKS. 

6.  Gently lift out the valve cone.

6b.  Turn the minimum screw counterclockwise to 

remove. Replace minimum screw.

7.  

Clean valve cone with solvent and re-grease 
with high temperature grease.

Note: 

Remove excess grease and check that holes 

in the core or body are not blocked. Open and 
close gas valve.

8.   Reverse procedure to reinstall.

Note: 

Replace in right position at top of valve.

 
 
 
 
 

Note: 

Check for leaks after reinstallation.

Re-grease Gas Valve/Minimum Screw Replacement (continued)

Valve Cone

Valve Cone

Minimum Screw

Notch

Correct Position

Содержание DGVU2004B-30

Страница 1: ...y responsibility for property damage or personal injury for improper service procedures done by an unqualified person Preferred Service This Base Manual covers general and speci c information includin...

Страница 2: ...re Using Cooktop 12 SERVICE DIAGNOSTICS AND PROCEDURES DGVU200 4B Parts Location Exterior 13 DGVU260 5B Parts Location Exterior 14 Parts Location Interior 15 Main Top Access 16 Spark Plug 17 Burner As...

Страница 3: ...safety messages will be preceded by a safety alert symbol and the word DANGER WARNING or CAUTION These words mean All safety messages will identify the hazard tell you how to reduce the chance of inju...

Страница 4: ...ough fth year from the date of original retail purchase will be repaired or replaced free of charge for the part itself with the owner paying all other costs including labor This does not include igni...

Страница 5: ...LE TO THIS PRODUCT ARE LIMITED IN DURATION TO THE PERIOD OF COVERAGE OF THE APPLICABLE EXPRESS WRITTEN LIMITED WARRANTIES SET FORTH ABOVE Some states do not allow limitations on how long an implied wa...

Страница 6: ...ed with the product To eld convert from natural or LP Propane the ori ce spuds and regulator must be physically changed Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3...

Страница 7: ...7 General Information Speci cations DGVU200 DGVU2600 Go to vikingrange com for latest speci cations 30 3 4 78 1 cm 28 1 2 72 4 cm 21 53 3 cm 4 10 2 cm 2 13 16 7 1 cm 7 3 16 18 4 cm 36 3 4 93 3 cm 21...

Страница 8: ...irth defects or other reproductive harm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed in the ame during combustion However exposure to a sma...

Страница 9: ...ctrician Note If electrical power is not supplied or is interrupted the open top burners will have to be lit manually with a match Gas Requirements Gas Connection U i 61 V i i and manufactured for use...

Страница 10: ...stem at test pressures equal to or less than 1 2 PSI 3 45kPa IMPORTANT NEVER refuse old connectors when installing this cooktop Rigid Connections U V L v i i the rear of the unit to the pressure regul...

Страница 11: ...es Gas 36 Wide Version 5 Burner Stainless Steel XXXXXX Serial Number Month Day Year of Manufacture Unit VIKING RANGE CORP G R E E N W O O D M I S S I S S I P P I 3 8 9 3 0 U S A M A D E I N T H E U S...

Страница 12: ...pen ame standing pilots Surface Burners Automatic Re ignition To light the surface burners push and turn the appropriate control knob counterclockwise to any position This control is both a gas valve...

Страница 13: ...GVU200 4B Parts Location Exterior Service Diagnostics and Procedures Burner Head 9 000 BTU Burner Head 15 000 BTU Control Knob Left Grate Assembly Burner Head 12 000 BTU Center Grate Assembly Burner H...

Страница 14: ...ing Preferred Service DGVU260 5B Parts Location Exterior Burner Head 12 000 BTU Burner Head 15 000 BTU Control Knob Left Grate Assembly Burner Head 4 000 BTU Burner Head 9 000 BTU Center Grate Assembl...

Страница 15: ...15 Operation Parts Location Interior Note DVGU260 5B shown Re igniter Module Terminal Block Manifold Pipe Assembly Gas Valve Gas Valve Burner Assembly Burner Assembly Burner Assembly Spark Plug Spark...

Страница 16: ...ps and burner heads 3 Remove securing screws under each burner head Remove main top 4 Reverse procedure to reinstall Note DVGU260 5B shown WARNING To avoid risk of electrical shock personal injury or...

Страница 17: ...ner assembly 5 Repair replace spark plug as necessary 6 Reverse procedure to reinstall Spark Plug Burner Assembly Connector Spring Spring WARNING To avoid risk of electrical shock personal injury or d...

Страница 18: ...nstall Note Make sure correct burner assembly size is reinstalled see Parts Location Exterior pages 13 14 for correct burner sizes Note DVGU260 5B shown WARNING To avoid risk of electrical shock perso...

Страница 19: ...te When reinstalling gas valve to manifold pipe assembly make sure that gas valve tting and manifold pipe assembly opening align correctly WARNING To avoid risk of electrical shock personal injury or...

Страница 20: ...rom gas tap assembly 4 Repair replace micro switch as necessary 5 Reverse procedure to reinstall WARNING To avoid risk of electrical shock personal injury or death disconnect gas supply and electrical...

Страница 21: ...on always check for gas leaks with soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS To access Gas Valve 1 Remove main top see Main Top Access section page 16 2 Remove micro switch...

Страница 22: ...AN OPEN FLAME TO CHECK FOR GAS LEAKS 6 Gently lift out the valve cone 6b Turn the minimum screw counterclockwise to remove Replace minimum screw 7 Clean valve cone with solvent and re grease with high...

Страница 23: ...racket securing screws 6 Remove securing screws and manifold end bracket WARNING To avoid risk of electrical shock personal injury or death disconnect gas supply and electrical power to unit before se...

Страница 24: ...e Main Top Access section page 16 2 Remove securing screws and ground wiring Slide cover forward to remove 3 Disconnect and label wiring Remove re igniter module securing screws 4 Repair replace re ig...

Страница 25: ...6 Remove and repair replace terminal block as necessary Note Loosen power cord screws if removing power cord from terminal block 7 Reverse procedure to reinstall WARNING To avoid risk of electrical s...

Страница 26: ...re regulator from cooktop 4 Repair replace pressure regulator as necessary 5 Reverse procedure to reinstall WARNING To avoid risk of electrical shock personal injury or death disconnect gas supply and...

Страница 27: ...n igniter Igniter wire Single point spark module Clean igniter and remove debris Repair replace wire Test module Igniters spark but no ame Gas supply valve Gas supply interrupted Verify gas supply val...

Страница 28: ...11 Viking Preferred Service Wiring and Schematics DGVU200 4B Wiring Diagram BR BR WH RD BL WH WH RD BL GR Ground Neutral 120C AV Line In WH RD WH BK Igniters Terminal Block Re Igniter Module Micro Swi...

Страница 29: ...g and Schematics 2011 Viking Preferred Service DGVU260 5B Wiring Diagram WH RD WH BK Igniters Terminal Block Re Igniter Module Micro Switches BR GR GR WH RD BL GY BR WH RD BL GY Ground Neutral 120C AV...

Отзывы: