Electrical Connections
This cooktop does not require a neutral
connection. If the cooktop is to be completely
enclosed in a cabinet, feed the cooktop cable
through the opening in the cabinet. Make the
electrical connection following the appropriate
steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in
the table on the right.
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper
wire by using special connectors designed
and Underwriters Laboratories-listed for
joining copper to aluminum. Follow the
electrical connector manufacturer's
recommended procedure.
2. Aluminum/copper connection must conform
with local codes and industry- accepted
wiring practices.
The flexible conduit (supplied) 3 feet long
(100 cm) located at the right rear of the cooktop
bottom box should be connected directly to
junction box.
DO NOT
cut the conduit. A U.L - or
CSA - listed conduit connector must be provided
at each end of the power supply cable (at the
cooktop and at the junction box.) A time delay
fuse or circuit breaker is recommended.
DO NOT
ground to a gas pipe.
DO NOT
have a
fuse in the grounding or neutral circuit. Fuse both
supply (phase) lines.
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 Volt 60 cycle
electrical system (properly circuit protected to
meet Local Codes of NFPA No.70) must be
provided. Unit must be properly grounded in
accordance with local wiring code. The chart
below recommends the minimum circuit protector
and wire size if the appliance is the only unit on
the circuit. If smaller sizes of wire are used, the
unit efficiency will be reduced and a fire hazard
may be created. It is advisable that the electrical
wiring and hookup be accomplished by a
competent electrician.
Be sure your appliance is properly installed and
grounded by a qualified technician. Ask your
dealer to recommend a qualified technician or
an authorized repair service. This cooktop does
not require a neutral connection. If the cooktop
Is to be completely enclosed In a cabinet, feed
the cooktop cable through the opening in the
cabinet. Make the electrical connection
following the appropriate steps for your
installation.
12
Improper connection of aluminum house
wiring to the copper leads can result in a
serious problem.
WARNING
ELECTRICAL SHOCK HAZARD
The models may be powered at 240V or
208V.
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the
product. Failure to do so could result in
death or electric shock.
WARNING
Recommended Minimum
KW Rating on
serial plate
Circuit protection
in amperes
Wire Size
(AWG)
0-4.8
20
12
4.9-6.9
30
10
7.0-9.9
40
8
10.0-11.9
50
8
12.0-14.9
60
6
Electrical Requirements