background image

IMPORTANT

4

Please Read and Follow

FIRE/EXPLOSION
HAZARD

IF THE INFORMATION IN

THIS MANUAL IS NOT

FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL

INJURY, OR DEATH.

DO NOT

store or use gasoline or other

flammable vapors and liquids in the

vicinity of this or any other appliance.

DANGER

ELECTRICAL GROUNDING
INSTRUCTIONS

The cooktop must be electrically grounded

in accordance with local codes or, in the

absence of codes, with the ANSI/NFPA

No. 70-latest edition. Installation should

be made by a licensed electrician. This

appliance is equipped with a three-prong

grounding plug for your protection against

shock hazard and should be plugged

directly into a properly grounded

receptacle.

DO NOT

cut or remove the

grounding prong from the plug.

For personal safety, this appliance
must be properly grounded. DO NOT
under any circumstances cut or
remove the third (ground) prong from
the power plug

.

WARNING

BURN HAZARD

The use of cabinets for storage above the

appliance may result in a potential burn

hazard. Combustible items may ignite,

metallic items may become hot and

cause burns. If a cabinet storage is to be

provided the risk can be reduced by

installing a range hood that projects

horizontally a minimum of 5” (12.7 cm)

beyond the bottom of the cabinets.

CAUTION

Содержание Designer DETU200

Страница 1: ...Viking Installation Guide Designer Built In Electric Cooktops...

Страница 2: ...__________________9 Clearance Dimensions Wood Composite or Steel Overlay ______________________________11 Electrical Requirements _____________________________________________________________12 Genera...

Страница 3: ...ational Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 Installers should leave these instructions w...

Страница 4: ...n This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle DO NOT cut or remove the grou...

Страница 5: ...G It is the customer s responsibility to contact a qualified electrical installer To assure that the electrical installation is Adequate and in conformity with national electrical code ANSI NFPA 70 la...

Страница 6: ...Dimensions 6 21 53 3 cm 30 3 4 78 1 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 28 71 1 cm 18 9 16 47 2 cm 12 30 5 cm 3 1 4 8 3 cm Power conduit 30 Electric Cooktop Note Dimension includes screw head...

Страница 7: ...Dimensions 7 21 53 3 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 36 3 4 93 4 cm 33 3 8 84 7 cm 18 9 16 47 2 cm 3 1 4 8 3 cm Power conduit 12 30 5 cm 36 Electric Cooktop Note Dimension includes screw head...

Страница 8: ...uld be fused separately 3 wire 240 208 120VAC 60Hz 60 amp connection Unit is equipped with No 10 ground wire in conduit Should be fused separately Maximum amp usage 240V 35 0 amps 8 4 kw 208V 30 3 amp...

Страница 9: ...9 16 87 2 cm max B 19 1 4 49 0 cm min to 19 5 8 49 8 cm max Cutout Dimensions Note Refer to the downdraft installation instructions Downdraft Dimensions DETU200 w DIPR100 DETU260 w DIPR160 A 28 3 4 73...

Страница 10: ...e vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wa...

Страница 11: ...1 4 cm Wall Installation Island Installation Clearance Dimensions Wood Composite or Steel Overlay The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This wou...

Страница 12: ...ation Batter march Park Quincy Massachusetts 02269 A three wire single phase 240 Volt 60 cycle electrical system properly circuit protected to meet Local Codes of NFPA No 70 must be provided Unit must...

Страница 13: ...nch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire gray or white colored wire proceed as follows 1 If local codes permit connect the...

Страница 14: ...s All wall coverings countertop and cabinets around the cooktop should withstand heat up to 200 F 90 C Keep appliance free from combustible materials gasoline and other flammable vapors Installation P...

Страница 15: ...ds beyond the outermost flange of the cooktop All corners should be covered with tape IMPORTANT 1 2 Optional Gasket Turn the cooktop upside down and place on the packaged foam top Note Make sure there...

Страница 16: ...to the corresponding leads in the junction box Electrical Connection Final Installation 3 wire 1a Neutral Green Black Red Connect the red and black leads from the unit conduit to the corresponding le...

Страница 17: ...to remove these film residues and any installation dust or debris before being used for food preparation A qualified installer should carry out the following checks h Check top surface elements 1 Glow...