Clearance Dimensions

General Information

Site Preparation

Note:

It is recommended that a thorough site

inspection be conducted prior to unpacking and
moving this appliance.

• Chamfer all exposed edges of decorative

laminate to prevent damage from chipping.

• Radius corners of cutout and file to Insure

smooth edges and prevent corner cracking.
Recommend 1/4“or 3/8“ diameter drill In each
corner.

• Rough edges, inside corners which have not

been rounded and forced fits can contribute to
cracking of the countertop laminate.

• Confirm available access to adequate power–

see electrical requirements

.

• Be sure that the countertop for this appliance

is level and cut according to the cutout
requirements and dimensions–

see cutout

requirements and dimensions

.

• All wall coverings, countertop and cabinets

around the cooktop should withstand heat up
to 200°F (90° C).

• Keep appliance free from combustible materials,

gasoline, and other flammable vapors.

Installation Procedure

Remove packaging materials and literature package
from the cooktop before beginning installation.
Remove Installation Instructions from literature pack
and read them carefully before you begin.

ELECTRICAL SHOCK
HAZARD

The models may be powered

at 240V or 208V.

WARNING

DO NOT

use an extension cord with this

appliance. Such use may result in fire,

electrical shock or other personal injury.

WARNING

14

Install junction
box so that it can
be reached
through the front
of cabinet.

*

THE CONDUIT IS 3 FEET LONG

The junction box must be located where it

will allow considerable slack in the

conduit for serviceability.

WARNING

Junction Box Location

*Note:

Minimum from bottom of countertop

and adjacent right-side cabinet to top of
junction box.

Содержание Designer DETU200

Страница 1: ...Viking Installation Guide Designer Built In Electric Cooktops...

Страница 2: ...__________________9 Clearance Dimensions Wood Composite or Steel Overlay ______________________________11 Electrical Requirements _____________________________________________________________12 Genera...

Страница 3: ...ational Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 Installers should leave these instructions w...

Страница 4: ...n This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle DO NOT cut or remove the grou...

Страница 5: ...G It is the customer s responsibility to contact a qualified electrical installer To assure that the electrical installation is Adequate and in conformity with national electrical code ANSI NFPA 70 la...

Страница 6: ...Dimensions 6 21 53 3 cm 30 3 4 78 1 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 28 71 1 cm 18 9 16 47 2 cm 12 30 5 cm 3 1 4 8 3 cm Power conduit 30 Electric Cooktop Note Dimension includes screw head...

Страница 7: ...Dimensions 7 21 53 3 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 36 3 4 93 4 cm 33 3 8 84 7 cm 18 9 16 47 2 cm 3 1 4 8 3 cm Power conduit 12 30 5 cm 36 Electric Cooktop Note Dimension includes screw head...

Страница 8: ...uld be fused separately 3 wire 240 208 120VAC 60Hz 60 amp connection Unit is equipped with No 10 ground wire in conduit Should be fused separately Maximum amp usage 240V 35 0 amps 8 4 kw 208V 30 3 amp...

Страница 9: ...9 16 87 2 cm max B 19 1 4 49 0 cm min to 19 5 8 49 8 cm max Cutout Dimensions Note Refer to the downdraft installation instructions Downdraft Dimensions DETU200 w DIPR100 DETU260 w DIPR160 A 28 3 4 73...

Страница 10: ...e vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wa...

Страница 11: ...1 4 cm Wall Installation Island Installation Clearance Dimensions Wood Composite or Steel Overlay The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This wou...

Страница 12: ...ation Batter march Park Quincy Massachusetts 02269 A three wire single phase 240 Volt 60 cycle electrical system properly circuit protected to meet Local Codes of NFPA No 70 must be provided Unit must...

Страница 13: ...nch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire gray or white colored wire proceed as follows 1 If local codes permit connect the...

Страница 14: ...s All wall coverings countertop and cabinets around the cooktop should withstand heat up to 200 F 90 C Keep appliance free from combustible materials gasoline and other flammable vapors Installation P...

Страница 15: ...ds beyond the outermost flange of the cooktop All corners should be covered with tape IMPORTANT 1 2 Optional Gasket Turn the cooktop upside down and place on the packaged foam top Note Make sure there...

Страница 16: ...to the corresponding leads in the junction box Electrical Connection Final Installation 3 wire 1a Neutral Green Black Red Connect the red and black leads from the unit conduit to the corresponding le...

Страница 17: ...to remove these film residues and any installation dust or debris before being used for food preparation A qualified installer should carry out the following checks h Check top surface elements 1 Glow...

Страница 18: ...ou will need it if service is ever required Model number ____________________________________________________________________________________ Serial number ____________________________________________...

Страница 19: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Страница 20: ...king Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20700 EN 10070...

Отзывы: