© 2011 Viking Preferred Service
43
Service Diagnostics and Procedures
Freezer Thermistor
To access freezer thermistor:
1.
Remove freezer drawer, baskets, and glide
adapters
(see Freezer Drawer, Baskets, and
Glide Adapters section, pages 39-41)
.
2. Remove thermistor cover from evaporator
cover.
3. Remove thermistor from thermistor cover.
4.
Remove evaporator cover
(see Evaporator
Cover section, page 46).
5. Disconnect
wiring.
6. Repair or replace thermistor.
7. Reverse procedure to reinstall.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Evaporator Cover
Thermistor
Cover
Thermistor
Wiring