background image

PRODUCT MANUAL

Designed, Manufactured and Supported in the USA

C O M M U N I C A T I O N   &   S E C U R I T Y   S O L U T I O N S

Add Time Controlled Alert Tones and

Emergency Tones to Your Paging System

Features

•  Accurate 24 hour digital time clock displays 

hours and minutes synced to AC power

•  User programmable 24 hour, 128 event timer in

two separate manually selected schedules

•  Programmable day of week on/off feature

•  Programmable single, double or triple alert 

tone output (selectable bong or buzzer)

•  Three contact closure controlled sounds:

1) Emergency siren (yelp) sound

2) Temporal (slow whoop) evacuation signal

*NFPA/ANSI compliant when used with       

supporting equipment

3) Doorbell (chime) sound

•  Volume controllable, 600 Ohm line level audio 

output

•  Non-volatile memory with 

four day clock backup

•  Two sets of DPDT relay contacts for muting 

paging or background music during alert tones or

timed relay events

•  Switchable 50 / 60 Hz operation

•  Switch for Daylight Saving Time

•  Timed Relay Mode

•  Signal the beginning and end of class periods, breaks,

and lunch periods for schools

•  Signal the beginning and end of shifts, breaks, and

lunch periods for factories and other businesses

•  Provides a doorbell and / or alarm sounds over an

existing paging system, for such applications as door
entry, fire, severe weather, etc.

•  Use with Viking's 

DVA-2WA

to provide timed

messages (

DOD 110

)

•  Timed relay controller used with Viking's 

C-25O 

and

C-500

controllers to automatically forward entry calls

at certain times of the day

Power:  

120V AC / 13.8V AC 1.25A UL listed adapter

provided

Dimensions:

5.25” x  3.6” x  1.75” (133mm x 91mm

x 44mm)

Weight:

2 lbs  (0.9 Kg)

Operating Temperature: 

32°F to 90°F (0°C to 32°C)

Humidity: 

5% to 95% non-condensing 

Connections:

12 position cage clamp terminal strip

Internal Clock Backup Time:

4 days

Time Base:

50/60Hz AC power line

Time Base  Backup Accuracy:

+/- 5 ppm

Audio Output:

600 Ohm with volume adjust

potentiometer, maximum level = 17 dBm / 5.4Vrms
across 600 Ohm load

Relay Output:

DPDT rated 30V DC @ 1A, 110V DC

@ 0.3A ,125V AC @ 0.5A (resistive loads)

CTG-1A

Clock Controlled 

Tone Generator

February 15, 2019

Applications

Specifications

www.VikingElectronics.com

Information: 715-386-8861

VIKING

Viking's model 

CTG-1A

is a clock controlled tone

generator designed to provide accurately timed
bong alert tones or buzzer alert tone sounds over
an existing paging system.

The 

CTG-1A

can be programmed to output single,

double or triple alert tones with up to 128 events
in a 24 hour period in two separate schedules.
These bong / buzzer sounds are ideal for
indicating the start and end of shifts, break times,
lunch periods, etc. for factories, schools, or any
business requiring an audible indication of
specified times.  Each day of the week can be
programmed to either on or off, allowing you to
turn off the alert tones during specific days of the
week (weekends, etc.) In place of sending tones,
the 

CTG-1A 

can operate in the Timed Relay Mode

to turn on or off the relay at certain times of the day.
The 

CTG-1A

has three contact closure inputs for

triggering an emergency siren, evacuation signal
or a doorbell sound.

Содержание CTG-1A

Страница 1: ...ly forward entry calls at certain times of the day Power 120V AC 13 8V AC 1 25A UL listed adapter provided Dimensions 5 25 x 3 6 x 1 75 133mm x 91mm x 44mm Weight 2 lbs 0 9 Kg Operating Temperature 32...

Страница 2: ...er setting an event time press SINGLE DOUBLE or TRIPLE to program 1 2 or 3 alert bongs buzzer sounds for that event time Timed Relay Mode After setting an event time press SINGLE to turn the relay on...

Страница 3: ...CEL button to speed up the selection Step 3 Leave the set time mode by pressing the MODE button Notes See Programing section O Daylight Savings Time for the correct setting of dip switch 4 for the cur...

Страница 4: ...Set dip switch 3 to off to program specific days to on or off in schedule 1 Step 3 With the day of the week flashing use the TIME and CANCEL buttons to select the day of the week you would like to se...

Страница 5: ...r off event Press and hold the or CANCEL to speed up the selection Step 4 Press the single ALERT TONE button if the displayed time is a relay on event time or the double or triple ALERT TONE buttons i...

Страница 6: ...When finished programming press the MODE button until the RUN indicator lights In the run mode all buttons except the MODE button are disabled and the current time will be displayed with the colon fl...

Страница 7: ...rate Day of Week programming Note The schedule selection should only be changed in the Time Mode With DIP switch 2 in the OFF positon the CTG 1A will produce the selected tones at the programmed times...

Страница 8: ...rogrammed in that schedule The Timed Relay Mode of the CTG 1A changes its operation to a clock controlled relay output device allowing the relay to be programmed to turn on or off at certain times of...

Страница 9: ...cond break then repeated a second time 3 second break then repeated a second time Triple E Evacuation Signal Temporal Slow Whoop D Siren Yelp C Doorbell Ding Dong On Off 300 ms 300 ms 300 ms 280 Hz 22...

Страница 10: ...Model C 250 Entry PhoneController with Call Forwarding DOD 172 S6 S7 S5 C LED1 C LED6 C LED2 C LED3 C LED5 C LED4 1 3 4 2 ON 5 C LED7 VIKING MODEL CTG 1A POWER 13 8V AC VOLUME SINGLE CANCEL DOUBLE TR...

Страница 11: ...A POWER 13 8V AC VOLUME SINGLE CANCEL DOUBLE TRIPLE MODE CLOCK CONTROLLED TONE GENERATOR VIKING ELECTRONICS HUDSON WI 54016 1 2 3 4 5 SCHEDULE 2 BUZZ RELAY MODE DST 60 HZ To switch or controller that...

Страница 12: ...LE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY...

Отзывы: