17
1
Measur
ement (A)
Measur
ement (A)
Me
asu
rem
ent
(A
)
+1
/4”
+1
/4”
(.64 cm)
(.64
cm
)
Measur
ement (A)
+1
/4”
(.64 cm)
X
2
Measure from floor to bottom
of the anit-tip opening located on the back of range.
This will be measurement (A).
Locate anti-tip bracket on rear wall with the top left corner at
measurement (A) plus 1/2” (1.3 cm) from the floor and “X” from
where the right side of range (facing range) is to be located.
Leveling/Adjustments/Alignments
(cont.)
WARNING
TIPPING HAZARD
To reduce the risk of property
damage or personal injury;
install anti-tipping device
provided in accordance with
the installation instructions
in this document. Device
must be engaged properly to
prevent product from tipping
over.
7
Set the high corner of range so that the top of side trim is
3/8” (0.95 cm) above countertop. Level range to high corner.
Anti-tip Device Installation
16
1
2
Measure the four corners in cutout area to verify if
flooring is level.
For uneven or sloped floors, level unit with metal shims
only, as the adjustment required may exceed
the thread available in the leg.
3
3/8”
3/8
”
(0.95 cm)
(0.9
5 c
m)
3/8”
(0.95 cm)
4
Move unit into opening.
Leveling/Adjustments/Alignment
5
Check that unit is level side to
side and front to back. Side trim of the high corner
must be 3/8” (0.95 cm) above countertop.
If leveling is required, move unit out of opening.
6
1
2
1
Lift unit and prop on wood blocks.
Range
Width
“X”
Dimension
36”
24-1/2” (62.2 cm)
48”
36-1/2” (92.7 cm)
3
Mark and drill holes where bracket will be located.