Probe Replacement
To replace the temperature probe, refer to the CONTROLLER REPLACEMENT section.
Shelf Removal
Remove the shelves and or drawers from any compartment by extending each to
its most open position. In the center of each slide a plastic lever can be found. On the right side, the
lever should be pressed downward, while on the left, it should go upward.
By pressing both levers at the same time, the self or drawer can be pulled out of the cabinet.
1. By depressing both levers at the same time, the shelf or drawer can continue to be pulled out of the
cabinet (Fig.1).
Fig. 1
Fig. 2
2. Remove each cabinet slide by first lifting the front out of the key slot, and then forward. (Fig.2).
Defrosting
In the event that the evaporator coil is covered with ice (not frost), a physical defrosting may be needed
to clear the coil. This condition may be the result of a door or drawer being left open, a failed tempera-
ture probe, door gasket leaks, or the refrigeration access hole not sealed.
CAUTION:
DO NOT ALLOW EXCESSIVE MOISTURE TO DRAIN INTO THE EVAPORATOR DRAIN
PAN. THE EVAPORATOR DRAIN PAN EMPTIES INTO A CONDENSATE PAN LOCATED IN THE
COMPRESSOR COMPARTMENT. IT IS SIZED FOR NORMAL USES AND MAY OVERFLOW AND
CAUSE WATER DAMAGE TO FLOORING.
DO NOT USE TOOLS TO DISLODGE OR REMOVE ICE.