PROXIMITY TO SIDE CABINET INSTALLATION

1.  This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.  

IMPORTANT

:

The

top grate support MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop.  

2.  The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical

surfaces above 36” (91.4 cm) high.  There must be a minimum of 6” (15.2 cm) side clearance from the rangetop to
such combustible surfaces above the 36” (91.4 cm) counter height.

3.  Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm) , the maximum wall

cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm)
above the 36” (91.4 cm) high countertop. 

4.  Wall cabinets above the rangetop must be a minimum of 36” (91.4 cm) above the rangetop cooking surface for the

full width of the rangetop.  This minimum height requirement does not apply if a rangehood is installed over the
cooking surface.

ELECTRICAL REQUIREMENTS

Check your national and local codes regarding this unit.  This rangetop is supplied with a 3 wire conduit which is
equipped with a No. 10 ground wire.  See next section for grounding instructions.  

This unit should be fused

separately. CAUTION:  

Be sure the electrical power is off from the breaker box to the junction box until the unit is

installed and ready to operate.  The junction box should be located as shown in the drawing and connected to a
suitable ground.  

B

A

B

VERT

7 1/2”

24” 

19.1 cm)

(61.0 cm)

DERT

5 3/4”

24 7/16”

(14.6 cm)

(62.1 cm)

A

4

Minimum clearances from adjacent combustible construction

•Cooking surface and below (36” [91.4 cm ] and below)

•Sides - 0”
•Rear - 0” with backguard or high shelf; 0” with island trim and non-combustible rear wall; 6” (15.2 cm) with

island trim and combustible rear wall.

•Top grate support - 36” (91.4 cm)

•Above cooking surface (above 36” [91.4 cm])

•Sides - 6” (15.2 cm)
•Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm)

above cooking surface.

•Wall cabinets directly above product must be minimum 36” (91.4 cm) above cooking surface

•Use range only with factory supplied legs.

Description

VESC306-4B

Overall Width

29 7/8” (75.9 cm)

Overall Height from Bottom

Base Height

To top of glass frame - Min. 35 7/8” (91.1cm) to  Max. 37 5/8” (95.6 cm)
[Legs adjust 1 3/4” (4.5cm)]

Additions to Base Height

To top of island trim -

add 1 1/4” (3.2 cm)

To top of backguard -  add 6” (15.2 cm)
To top of high shelf -

add 23 1/2” (59.7 cm)

Overall Depth from Rear

To end of side panel - 

24 5/16” (61.8 cm)

To end of control panel - 

26 1/4” (66.7 cm)

To end of knobs - 

27 3/4” (70.5 cm)

Electrical Requirements

240-208/120 VAC/60Hz - Connect with locally supplied 3-wire, flexible cord
rated 60 amp 125-250 minimum.  Cord must be agency approved for use with
household electric ranges.

Maximum Amp Usage

240V - 58.5 amps

208V - 50.7 amps

Preheat Rating

240V - 24.0 amps

208V - 20.8 amps

Surface Element Rating

240V

Left Front

1500 watts

Left Rear

2400 watts

Right Front

1800 watts

Bridge

800 watts

Right Rear

1800 watts

Broil Rating

240V

Maxi Broil - (8 Pass) 

3000 watts

Mini Broil - (4 Pass)

1250 watts

Bake Rating (partial power from 
broil element

240V - 2935 watts

Convection Cook Rating

240V - 2200 watts

Oven Interior Dimension

Width -

23” ( 58.4 cm)

Height - 

16 1/8” (41.1 cm)

Depth - 

15 3.8” (39.1 cm)

Overall size - 

3.3 cu. ft.

Approximate Shipping Weight

424 lb. (190.8 kg.

SPECIFICATIONS - ELECTRIC RANGE

Содержание VERT301-4B

Страница 1: ...485L EN 021808J Electric Ranges Rangetops Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking...

Страница 2: ...ove cooking surface Wall cabinets directly above product must be minimum 36 91 4 cm above cooking surface It is not recommended to install two or more units side by side IMPORTANT PLEASEREADANDFOLLOW...

Страница 3: ...jacent combustible construction Cooking surface and below 36 91 4 cm and below Sides 0 Rear 0 with backguard or high shelf 0 with island trim and non combustible rear wall 6 15 2 cm with island trim a...

Страница 4: ...Ventilator Installation The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the ceramic glass surface This would typically result in the bottom of the hood being 66 167 6 cm...

Страница 5: ...RUCTIONS 8 PROXIMITY TO SIDE CABINET INSTALLATION 1 This range may be installed directly adjacent to existing 36 91 4 cm high base cabinets IMPORTANT The top grate support MUST be 3 8 95 cm above the...

Страница 6: ...e range 3 Wire Power Supply Cord 1 Remove access door 2 Remove supply cord strain relief bracket and 3 supply cord mounting screws on the terminal block 3 Feed supply cord up thru the hole in the bott...

Страница 7: ...nge Terminal is not required on grounding wire if used with ground washer 5 Remove 3 mounting screws and green grounding screw Cut off and discard ground strap Attach line 1 red to the left terminal l...

Страница 8: ...lf cleaning FINAL PREPARATION 1 Some stainless steel parts may have a plastic protective wrap which must be removed The interior of the oven should be washed thoroughly with hot soapy water to remove...

Отзывы: