manualshive.com logo in svg
background image

PROXIMITY TO SIDE CABINETS

1.  The cooktop may be installed directly to existing base cabinets.
2.  The cooktop 

CANNOT

be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical

surfaces above 36” (91.4 cm) high. There must be a minimum of 8” (20.3 cm) side clearance from the cooktop to
such combustible surfaces above the 36” (91.4 cm) counter height.

3.  Within the 8” (20.3 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall

cabinet depth must be 13” (33.0 cm) and wall cabinets within this 8” (20.3 cm) side clearance must be 18” (45.7 cm)
above the 36” (91.4 cm) high countertop.

4.  Wall cabinet above the cooktop must be a minimum of 36” (91.4 cm) above the countertop for a full width of the

cooktop. This minimum height requirement does not apply if a rangehood is installed over the cooking surface.

5.  A 120 volt wall receptacle should be located approximately 6” (15.2 cm) below the countertop cutout and 12” 

(30.5 cm) from the right side of the cutout.

MINIMUM CLEARANCES FROM ADJACENT COMBUSTIBLE CONSTRUCTION

•Above countertop (above 36” [91.4 cm])

•Sides 8” (20.3 cm)
•Rear - See chart dimension “A”
•Within 8” (20.3 cm) side clearance. Wall cabinets no deeper than 13” (33.0 cm)
•Must be minimum 18” (45.7 cm) above countertop
•Wall cabinets directly above the product must be minimum 36” (91.4 cm) above the countertop.

5

13” max.
(33.0 cm)

36” min.
(91.4 cm)

18” min.
(45.7 cm)

8” min. 
(20.3 cm)

3-1/8”
(7.9 cm)

36” min.
(91.4 cm)

A

VGSU

3-1/2” (8.9 cm) min.

DGCU/DGSU

2-1/2” (6.4 cm) min.

A

4

GENERAL INFORMATION

1.  

WARNING

The use of cabinets for storage above the appliance may result in a potential burn hazard.

Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be
provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.

2. 

WARNING

This appliance shall not be used for space heating. This information is based on safety

considerations.

3.  All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.
4.  Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.
5.  Do not obstruct the flow of combustion and ventilation air.
6.  Disconnect the electrical supply to the appliance before servicing.
7.  When removing cooktop for cleaning and/or service;

A.  Shut off gas at main supply
B.  Disconnect AC power supply
C.  Disconnect gas line to the inlet pipe.
D.  Lift appliance out of cabinet cutout.

8.  

Electrical Requirement

Normal grounded household current, 120 volts, 60 Hz, 15 amps, single phase. Electrical installation should
comply with national and local codes.

9.  

Air Supply and Ventilation

Means must be provided for any heavy-duty cooking appliance to exhaust combustion waste product to the
outside of the building. It is recommended that the cooktop be set under a powered, vented exhaust hood, or
non-vented recirculating hood. Nothing should obstruct the flow of combustion and ventilation air.

10.  

Gas Manifold Pressure

Natural gas - 5.0” W.C.P.

11.  

Flexible Connections

If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a
flexible connector of at least 1/2” I.D. (1.3 cm) NPT with suitable strain reliefs and comply with ANSI Z21.41
and Z21.69 standards. 

DESCRIPTION

DGSU100   (30” W.) 

DGSU160  (36” W.)

Cutout Width - Minimum 

29-1/8” (74.0 cm)

34-7/8” (88.6 cm)

Maximum

29-7/8” (75.9 cm)

35-7/8” (91.1 cm)

Cutout Height - Minimum

3-1/8” (7.9 cm)

Cutout Depth - Minimum

19-3/4” (50.2 cm)

Maximum

20-1/8” (51.1cm)

Overall Width

30-3/4” (78.1 cm)

36-3/4” (93.3 cm)

Overall Height from Bottom 

4-3/8” (10.5 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit DLPK to convert to LP. 

Uses standard residential 1/2” (1.3 cm)

I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

14,000 Nat./13,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

(3.5 Nat./2.8 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

10,000 Nat./LP (BTU) 

(3.5 Nat./2.8 LP [kw])

(2.9 Nat./LP [kw])

Center Front/Rear

N/A

14,000 Nat./13,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

Right Rear-   

8,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

(2.1 Nat./LP [kw])

(2.1 Nat./LP [kw])

Right Front-  

6,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

(1.8 Nat./LP [kw]) 

(1.8 Nat./LP [kw])

Approximate Shipping Weight

49 lb. (22.0 kg.)

74 lb. (33.3 kg)

Содержание DGCU105

Страница 1: ...Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Installation Guide Built In Gas Cooktops ...

Страница 2: ...m product This may void the warranty 3 Please observe all local and national codes and ordinances 4 Please ensure that this product is properly grounded 5 The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSI Z223 1 or ...

Страница 3: ...e and other flammable vapors 5 Do not obstruct the flow of combustion and ventilation air 6 Disconnect the electrical supply to the appliance before servicing 7 When removing cooktop for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Lift appliance out of cabinet cutout 8 Electrical Requirement Normal grounded household ...

Страница 4: ...OVERLAY INSTALLATION The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the rangehood installation instructions for further information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 30 76 2 cm min 36 91...

Страница 5: ...3 36 min cutout VESO166 36 min cutout OPTIONAL INSTALLATION OF GASKET If desired the gasket can be installed to eliminate the space between the countertop and the cooktop This will help prevent spillovers into the cabinet underneath the cooktop 1 Remove the roll of gasket material from your packed with items 2 Turn your cooktop upside down on a flat surface Make sure to place some protective mater...

Страница 6: ...2 5 cm 1 1 4 3 2 cm 5 3 8 13 7 cm 4 1 4 10 8 cm DGCU Height Dimension NOTE Minimum cutout height when using a 90 elbow supplied by installer 5 5 8 14 3 cm DGCU CUTOUT DIMENSIONS Cutout Opening B Min Max 30 W 28 3 4 73 0 cm 29 7 8 75 9 cm 36 W 34 1 2 87 6 cm 35 7 8 91 1 cm 45 W 42 7 8 108 9 cm 44 1 8 112 1 cm B 30 W Model 28 3 4 73 0 cm 36 W Model 34 1 2 87 6 cm 45 W Model 42 7 8 108 9 cm 19 11 16 ...

Страница 7: ... 7 cm 1 3 4 4 5 cm 36 3 4 93 4 cm 12 Cutout Opening 19 3 4 50 2 cm Minimum 20 1 8 51 1 cm Maximum DGSU CUTOUT DIMENSIONS DGSU BURNER BOX DIMENSIONS Electric Cord 48 121 9 cm Gas Inlet 1 1 16 2 7 cm 1 1 16 2 7 cm 3 1 16 7 8 cm 30 W Model 29 1 8 74 0 cm 36 W Model 34 7 8 88 6 cm 19 3 4 50 2 cm C C Min Max 30 W 29 1 8 74 0 cm 29 7 8 75 9 cm 36 W 34 7 8 88 6 cm 35 7 8 91 1 cm ...

Страница 8: ... to this intake pipe not supplied to the regulator supplied but not connected through the cooktop In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector b Double check any installer supplied intake pipes visually and or blow them out with compressed air to clear any dirt particles threading chips or other foreign matter before installing in a service line Th...

Страница 9: ...s turn the knob counter clockwise to any position 2 Upon ignition of the surface burner turn the knob to the desired position HI Med or Low 3 To shutdown the burner turn knob clockwise to the OFF position 4 In case of failure shut the gas OFF using the installer supplied manual shut off valve FINAL PREPARATION a New units are cleaned atthe factory to remove any visible signs of dirt oil grease etc...

Страница 10: ...19 18 ...

Отзывы: