manualshive.com logo in svg
background image

3

DESCRIPTION

DGCU105   (30” W.) 

DGCU165  (36” W.)

DGCU155  (45” w.)

Cutout Width - Minimum 

28-3/4” (73.0 cm)

34-1/2” (87.6 cm)

42-7/8” (108.9 cm)

Maximum

29-7/8” (75.9 cm)

35-7/8” (91.1 cm)

44-1/8” (112.1 cm)

Cutout Height - Minimum

2-3/4” (7.0 cm)

Cutout Depth - Minimum

19-11/16” (50.0 cm)

Maximum

20-1/2” (52.1cm)

Overall Width

30-3/4” (78.1 cm)

36-3/4” (93.3 cm)

45” (114.3 cm)

Overall Height from Bottom 
(including connector)

4-1/4” (10.8 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

Not field convertible - Must be ordered from factory either natural or LP/Propane. 

Uses

standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

14,000 Nat./13,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

(3.5 Nat./2.8 LP [kw])

(3.5 Nat./2.8 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

10,000 Nat./LP (BTU) 

8,000 Nat./LP (BTU)

(3.5 Nat./2.8 LP [kw])

(2.9 Nat./LP [kw])

(2.1 Nat./LP [kw])

Left Center

N/A

14,000 Nat./13,500 LP (BTU)

10,000 Nat./LP (BTU)

(4.1 Nat./4.0 LP [kw])

(2.9 Nat./LP [kw])

Right Center

N/A

N/A

14,000 Nat./13,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

Right Rear-   

8,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

(2.1 Nat./LP [kw])

(2.1 Nat./LP [kw])

(1.8 Nat./LP [kw])

Right Front-  

6,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

(1.8 Nat./LP [kw]) 

(1.8 Nat./LP [kw])

(2.1 Nat./LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

93 lb. (41.9 kg)

DESCRIPTION

VGSU103   (30” W.) 

VGSU163 (36” W.)

Cutout Width - Minimum 

26-7/8” (68.3 cm)

34-3/8” (87.3 cm)

Maximum

29-7/8” (75.9 cm)

35-7/8” (91.1 cm)

Cutout Height - Minimum

2-1/2” (6.4 cm)

Cutout Depth - Minimum

18-5/8” (47.3 cm)

Maximum

20-1/8” (51.1cm)

Overall Width

30-3/4” (78.1 cm)

36-3/4” (93.3 cm)

Overall Height from Bottom 

5” (12.7 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.

Uses standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

16,000 Nat./15,500 LP (BTU)

16,000 Nat./15,500 LP (BTU)

(4.8 Nat./4.65 LP [kw])

(4.8 Nat./4.65 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU) 

(3.6 Nat./3.45 LP [kw])

(3.6 Nat./3.45 LP [kw])

Center Front/Rear

N/A

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP [kw])

Right Rear-   

8,000 Nat./7,500 LP (BTU)

8,000 Nat./7,500 LP (BTU)

(2.4 Nat./2.25 LP [kw])

(2.4 Nat./2.25 LP [kw])

Right Front-  

6,000 Nat./5,500 LP (BTU)

6,000 Nat./5,500 LP (BTU)

(1.8 Nat./1.65 LP [kw]) 

(1.8 Nat./1.65 LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

BASIC SPECIFICATIONS

1.  Before beginning, please read these instructions completely and carefully.
2.  Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.
3.  Please observe all local and national codes and ordinances.
4.  Please ensure that this product is properly grounded.

5.  The installer should leave these instructions with the consumer who should retain for local inspector’s use

and for future reference.

Installation must conform with local codes or, in the absence of codes, the National Fuel Gas Code, ANSI Z223.1 or the
latest edition. 

In Canada:

Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation

codes and/or local codes. Electrical installation must be in accordance with the current CSAC22.1 Canadian Electrical
Codes Part 1 and/or local codes.

Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be
installed in the gas supply line ahead of the cooktop in the gas stream for safety and ease of service.

In Massachusetts:

All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” handle

type manual gas valve must be installed in the gas supply line to the appliance.

1.  Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

2.  

WHAT TO DO IF YOU SMELL GAS:

•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone

in your building.

•Immediately call your gas supplier from a neighbor’s

phone.

•Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire

department.

3.  Installation and service must be performed by a qualified

installer, service agency, or the gas supplier.

WARNING

If not installed, operated and maintained in
accordance with the manufacturer’s instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness and which are known to
cause cancer, birth defects, or other reproductive
harm.

WARNING:  

IF THE INFORMATION IN THIS

MANUAL IS NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR
DEATH.

For example, benzene is a chemical which is
part of the gas supplied to the cooking
product. It is consumed in the flame during
combustion. However exposure to a small
amount of benzene is possible if a gas leak
occurs. Formaldehyde and soot are by-
products of incomplete combustion. Properly
adjusted burners with a bluish rather than
yellow flame will minimize incomplete
combustion.

WARNING!!

ELECTRICAL GROUNDING INSTRUCTIONS

The cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the
ANSI/NFPA No. 70-latest edition. Installation should be made by a licensed electrician. This appliance is equipped with
a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly
grounded receptacle. Do not cut or remove the grounding prong from the plug.

For personal safety, this appliance must be properly grounded.  Do not under any

circumstances cut or remove the third (ground) prong from the power plug.

2

IMPORTANT:  PLEASE READ AND FOLLOW

Содержание DGCU105

Страница 1: ...Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Installation Guide Built In Gas Cooktops ...

Страница 2: ...m product This may void the warranty 3 Please observe all local and national codes and ordinances 4 Please ensure that this product is properly grounded 5 The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSI Z223 1 or ...

Страница 3: ...e and other flammable vapors 5 Do not obstruct the flow of combustion and ventilation air 6 Disconnect the electrical supply to the appliance before servicing 7 When removing cooktop for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Lift appliance out of cabinet cutout 8 Electrical Requirement Normal grounded household ...

Страница 4: ...OVERLAY INSTALLATION The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the rangehood installation instructions for further information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 30 76 2 cm min 36 91...

Страница 5: ...3 36 min cutout VESO166 36 min cutout OPTIONAL INSTALLATION OF GASKET If desired the gasket can be installed to eliminate the space between the countertop and the cooktop This will help prevent spillovers into the cabinet underneath the cooktop 1 Remove the roll of gasket material from your packed with items 2 Turn your cooktop upside down on a flat surface Make sure to place some protective mater...

Страница 6: ...2 5 cm 1 1 4 3 2 cm 5 3 8 13 7 cm 4 1 4 10 8 cm DGCU Height Dimension NOTE Minimum cutout height when using a 90 elbow supplied by installer 5 5 8 14 3 cm DGCU CUTOUT DIMENSIONS Cutout Opening B Min Max 30 W 28 3 4 73 0 cm 29 7 8 75 9 cm 36 W 34 1 2 87 6 cm 35 7 8 91 1 cm 45 W 42 7 8 108 9 cm 44 1 8 112 1 cm B 30 W Model 28 3 4 73 0 cm 36 W Model 34 1 2 87 6 cm 45 W Model 42 7 8 108 9 cm 19 11 16 ...

Страница 7: ... 7 cm 1 3 4 4 5 cm 36 3 4 93 4 cm 12 Cutout Opening 19 3 4 50 2 cm Minimum 20 1 8 51 1 cm Maximum DGSU CUTOUT DIMENSIONS DGSU BURNER BOX DIMENSIONS Electric Cord 48 121 9 cm Gas Inlet 1 1 16 2 7 cm 1 1 16 2 7 cm 3 1 16 7 8 cm 30 W Model 29 1 8 74 0 cm 36 W Model 34 7 8 88 6 cm 19 3 4 50 2 cm C C Min Max 30 W 29 1 8 74 0 cm 29 7 8 75 9 cm 36 W 34 7 8 88 6 cm 35 7 8 91 1 cm ...

Страница 8: ... to this intake pipe not supplied to the regulator supplied but not connected through the cooktop In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector b Double check any installer supplied intake pipes visually and or blow them out with compressed air to clear any dirt particles threading chips or other foreign matter before installing in a service line Th...

Страница 9: ...s turn the knob counter clockwise to any position 2 Upon ignition of the surface burner turn the knob to the desired position HI Med or Low 3 To shutdown the burner turn knob clockwise to the OFF position 4 In case of failure shut the gas OFF using the installer supplied manual shut off valve FINAL PREPARATION a New units are cleaned atthe factory to remove any visible signs of dirt oil grease etc...

Страница 10: ...19 18 ...

Отзывы: