manualshive.com logo in svg
background image

Use / Installation

Built-In Gas Outdoor Wok/Cooker

VGWTO5

241 

CVGWTO5

241

Содержание CVGWTO5241

Страница 1: ...Use Installation Built In Gas Outdoor Wok Cooker VGWTO5241 CVGWTO5241 ...

Страница 2: ...ak is not a do it yourself procedure Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician 7 The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tub...

Страница 3: ...he utensil scorching the outside of the utensil and making cleanup harder 10 The flame of the surface burner should be adjusted to just cover the bottom of the pan or pot Excessive burner setting may cause scorching of adjacent countertop surfaces as well as the outside of the utensil This is based on safety considerations 11 Use dry pot holders Moist or damp potholders on hot surfaces may result ...

Страница 4: ...s Requirements Natural standard residential 1 2 1 3 cm ID gas service line LP Propane standard residential 1 2 1 3 cm ID gas service line or equipped with high capacity hose regulator assembly for connection to standard 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection Unit must be ordered Natural or LP Propane Not Field Convertible 12 V 8 AA batteries Electrical Requirements Burner Ratin...

Страница 5: ...ruction where an LP Propane tank is going to be used there MUST be some type of support braces cut out etc to prevent tank from moving within the installation The support must also allow the LP Propane tank to withstand a horizontal tipping force equal to the weight of the tank without tipping over The tank can not tip over or deflect more than 1 00 inch when a 38 lb horizontal force is applied to...

Страница 6: ...as shut off valve must be installed in an easily accessible location All installer supplied parts must conform to local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 latest edition Installation in Canada must be in accordance with the current CAN CGA B149 1 Natural Gas Installation Code or CAN CGA B149 2 Propane Installation Code and or local codes All connectors n...

Страница 7: ...to check on type and size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 7 8 2 2 cm female flare adaptor to the 7 8 2 2 cm male flare adaptor on the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the u...

Страница 8: ...nd size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 3 8 female flare adaptor to the 3 8 male flare adaptor to the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Con...

Страница 9: ...or to the LP Propane tank Open the tank valve and check the connection between the regulator and the Type 1 QCC 1 fitting for leaks with a soapy water solution If bubbles appear tighten the connection Repeat until all leaks have been stopped ALWAYS CHECK FOR LEAKS AFTER EVERY LP PROPANE TANK CHANGE Any joint sealant used must be an approved type and be resistive to the actions of LP Propane gas LP...

Страница 10: ...duce the air and to prevent a noisy flame that lifts off the burner 5 Turn the surface burners off 6 Tighten the air shutter screws 7 Replace the grate support and grate A B 3 4 1 91 cm Air Shutter Orifice Initial Ignition of Burners All appliances are tested before leaving the factory Field adjustments may be necessary for proper mixture of gas and air for proper operation When the unit is connec...

Страница 11: ...ers will ignite at any on position with the automatic reignition system If the flame goes out for any reason the burners will automatically reignite if the gas is still flowing When gas is permitted to flow to the burners the electric igniters start sparking On all surface igniters you should hear a clicking sound If you do not turn off the control and check that the unit is plugged in and that th...

Страница 12: ... the front right side interior of the unit Loosen the head screws to remove the lid which is connected to 8 AA batteries After replacing the batteries reattach the lid with the screws Replace the pan burner bowls and grates Note Please be environmentally conscious dispose of old batteries properly Replacing Batttery Pack ...

Страница 13: ...e graphics from the control panel Use hot soapy water and a soft clean cloth Control Knobs MAKE SURE THE CONTROL KNOBS POINT TO THE OFF POSITION BEFORE REMOVING Pull the knobs straight off Wash in detergent and warm water Do not soak knobs Dry completely and replace by pushing firmly onto stem Stainless Steel Parts All stainless steel parts should be wiped regularly with hot soapy water at the end...

Страница 14: ...ervice is ever required The serial number and model number for your wok cooker is located on the left rear side of the burner box Model Number ___________________________________________Serial Number_____________________________________ Date of Purchase __________________________________________Date Installed _____________________________________ Dealer s Name _____________________________________...

Страница 15: ...owner of the product during the term of the warranty and applies to products purchased and located in the United States and Canada Products must be purchased in the country where service is requested If the product or one of its component parts contains a defect or malfunction during the full warranty period after a reasonable number of attempts by the warrantor to remedy the defect or malfunction...

Страница 16: ... 101515 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking website at vikingrange com in the US or brigade ca in Canada ...