To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
LED driver board (Phase 2)
Upper
EOC4 Com
Lower
EOC4 Com
Upper Cycle
LED Output
Upper Temp
LED Output
Lower Cycle
LED Output
Lower Temp
LED Output
Programming
connector
Power
Supply
P1 Upper Cycle LED output
Pin 1
Output
Upper cycle output signal
Blk
Pin 2
12 VDC
12 Vdc output-voltage source to anode of
knob LED light ring
Red
P2 Programing connector - Factory use only
These
connections are
reversed from
Phase 1 board
Troubleshooting
24
©2015 Viking Range, LLC
Содержание CVDOF730