![background image](http://html1.mh-extra.com/html/viking-range/cvdof730/cvdof730_service-manual_1026301019.webp)
Selector Chart
Resistance checks are made on the selector wire harness with the selector wire harness
disconnected from the board at location P14 and thermostat disconnected. The harness is
connected to P14 for voltage checks.
Selector Position
Resistance - Voltage
blue to yellow
Resistance - Voltage
blue to black
Resistance - Voltage
black to yellow
Off
10.0 k
W
5 VDC
∞
5 VDC
∞
0
Bake
10.0 k
W
5 VDC
374
W
0.24 VDC
9.48 k
W
4.74 VDC
Convection Bake
10.0 k
W
5 VDC
1.60 k
W
0.86 VDC
8.42 k
W
4.12 VDC
Tru Convection
10.0 k
W
5 VDC
2.60 k
W
1.47 VDC
7.28 k
W
3.49 VDC
Convection Roast
10.0 k
W
5 VDC
3.85 k
W
2.08 VDC
6.01 k
W
2.88 VDC
Convection Broil
10.0 k
W
5 VDC
5.00 k
W
2.64 VDC
4.81 k
W
2.31 VDC
Hi Broil
10.0 k
W
5 VDC
6.14 k
W
3.21 VDC
3.78 k
W
1.80 VDC
Med Broil
10.0 k
W
5 VDC
7.20 k
W
3.66 VDC
2.72 k
W
1.26 VDC
Low Broil
10.0 k
W
5 VDC
8.28 k
W
4.21 VDC
1.58 k
W
0.77 VDC
Self Clean / Proof
10.0 k
W
5 VDC
9.41 k
W
4.82 VDC
443
W
0.22 VDC
OFF
BAKE
CONV BAKE
TRU CONV
CONV ROAST
CONV BROIL
MAX BROIL
MED BROIL
LOW BROIL
SELF CLEAN
OR PROOF
Selector Switch, 10 position
Troubleshooting
19
©2015 Viking Range, LLC
Содержание CVDOF730