1.15.4 Classification
1.15.5 Power Inrush
1.15.6 Port Priority
1.15.7 Violation Type
1.15.8 Max Power
1.15.9 Disable
1.15.10 Enable
1.15.11 Force Power
1.15.12 Apply
Selects the PD classification type to be used:
“Bypass” for ignoring classification.
“.3AF/AT” for IEEE 802.3af/at classification signature.
Selects the “Power Inrush” mode of the port:
“Normal” for IEEE 802.3af mode.
“High Inrush” for legacy devices, which require more than 15.4W. For the
port to deliver more than 15.4W appropriately, the ILIM/ICUT value needs
to be selected and classification needs to be bypassed.
“Pre 802.3at” for devices supporting 802.3at. For the port to deliver more
than 15.4W appropriately, the ILIM/ICUT value to be selected.
Port Priority is used in situations where the total power requested by all connected
devices may exceed the total power available from the Midspan. By entering a value
between 0 to 3, the user can give a higher priority to deliver power to some ports.
Less critical ports can be set with a lower priority. Ports with the priority set to 3
have the highest priority and 0 is the lowest.
Selects the violation type to be used by the port during delivering state:
“None” for bypassing violation checking.
“Class Based” for limiting power based on the classification results. If
classification is bypassed, then “Class-0” will be used in Normal Mode and
“ILIM/ICUT” values in High power mode.
“User Defined” for limiting power based on user defined value.
Enter the user defined power value.
This value can only be changed or used if the
“Violation Type” is set to “User Defined”.
This button disables the port. Buttons “Disable”, “Enable”, and “Force Power” are
mutually exclusive.
This button enables the port. Buttons “Disable”, “Enable”, and “Force Power” are
mutually exclusive.
This button forces the port to output power. This will bypass detection,
classification, and power management checks. No violation will be honored. Buttons
“Disable”, “Enable”, and “Force Power” are mutually exclusive.
Applies the user selected configuration onto the selected port.