background image

VZ-WM60

Page 6 

Visit the ViewZ website at http://www.viewzusa.com

 

Installation Instructions

Wood Stud Installation

Stud

Electronic 
Studfinder

1/2” Socket 
Wrench

Wall Plate

5/16” Lag Bolt 
and Flat Washer

1/4” Drill 
Bit

Visual Centering 
Diamond

It is recommended that two people perform the installation. One person should hold the mount while the other person 
installs the wall plate.

Visual Centering Diamond -

 The visual centering diamond will guide you in determing the screen placement on the wall. 

Step 1.  The visual centering diamond will help 
 

you visualize the center of your flat  

 

panel.  Place the wall plate against the  

 

wall in the desired viewing location and  

 

mark the center of the visual centering  

 diamond.
Step 2.  If the location is acceptable, use a stud  
 

finder to determine the exact center of  

 

each stud. 

Step 3.  Once all of the studs have been located,  
 

adjust the wall plate to match the closest  

 

location of the center diamond mark  

 

while hitting at least two found stud  

 

positions with the mount. Use a pencil to  

 

mark these mounting locations.

Step 4.  Using a 1/4” drill bit, drill a pilot hole at  
 

the first aligned and marked location.

Step 5.  Insert one (1) 5/16” x 3” lag bolt and 
 

washer into the mounting hole and  

 

tighten (see WARNING: below) using a  

 

1/2” socket.

Do NOT over-tighten lag bolts when 

attaching the mount to the wall.  

Improper installation may result 

in personal injury or damage to 

 

property.

Only use 1/4” drill bit when drilling 
the pilot holes.

Содержание VZ-WM60

Страница 1: ... AMERICA 177 W Orangethorpe Ave Placentia CA 92870 USA USA and Canada Phone 1 888 99 ViewZ Other Locations Phone 001 714 996 1177 Fax 001 714 996 1138 VZ WM60 Universal Low Profile Flat Mount for 40 to 55 ViewZ Monitors 853177002847 ...

Страница 2: ...SSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY At least two qualified people should perform the assembly procedure Injury and or damage can result from dropping or mishandling the flat panel If mounting to studs make sure that the mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is recommended Beawareofthemountingenvironment Ifdrillingand orcuttingintothem...

Страница 3: ...inning installation If there are parts missing and or damaged please stop the installation and contact ViewZ 888 99 ViewZ Installation Tools not supplied Wall Plate Qty 1 Security Bar Qty 1 Mounting Brackets Qty 2 Universal Washers Qty 6 5 16 x 3 Lag Bolts Qty 6 Flat Washers Qty 6 Universal Spacers Qty 24 Fixed Tilt Bracket Qty 2 Phillips Screwdriver 1 4 Drill Bit Electronic Stud Finder Drill Leve...

Страница 4: ... x 30mm Qty 6 M4 x 16mm Qty 6 M6 x 45mm Qty 6 M6 x 30mm Qty 6 M6 x 25mm Qty 6 M6 x 16mm Qty 6 M5 x 30mm Qty 6 M5 x 25mm Qty 6 M5 x 16mm Qty 6 M8 x 70mm Qty 4 M8 x 45mm Qty 6 M8 x 30mm Qty 6 M8 x 25mm Qty 6 M8 x 16mm Qty 6 If your unit requires alternative mounting hardware use commercially available hardware or contact ViewZ 888 99 ViewZ ...

Страница 5: ...exact center of your flat panel on the wall Low Profile Design Holds the flat panel less than 1 from the wall Cable Electrical Cut Out Large cut outs on the wall plate allow for easy cable access and power distribution Universal Spacers Uniquely designed spacers that fit multiple screw sizes Mounting Slots Allow for a variety of stud configurations and lateral shift adjustments when mounting your ...

Страница 6: ...n the desired viewing location and mark the center of the visual centering diamond Step 2 If the location is acceptable use a stud finder to determine the exact center of each stud Step 3 Once all of the studs have been located adjustthewallplatetomatchtheclosest location of the center diamond mark while hitting at least two found stud positionswiththemount Useapencilto mark these mounting locatio...

Страница 7: ...damage to property Step 1 Place the wall plate into position against the wall keeping it level Step 2 Mark off four holes to be used for securing the mount and place the wall plate aside Solid Surface Cinder Block Step 3 Next drill holes using an electric drill and masonry bit The drill bit size that is used will depend on the size of the hardware used Step 4 Insert a concrete anchor into each hol...

Страница 8: ...e and verify the depth of the remaining thread inserts Step 4 Locate the correct diameter screw for the thread insert Step 5 Compare your thread depth indicator marking to the screw length Figure 1 Figure 2 Figure 3 Inverted Flat Panel Display Marking the Depth Thread Insert Thread Depth Indicator Thread Depth Indicator Marking Screw Marking Screw Thread Depth Indicator When using the universal sp...

Страница 9: ...rsal spacer can fit M4 M5 M6 and M8 screws sizes You may not need to use any spacers for your particular flat panel The universal washer will fit M4 M5 M6 and M8 hole patterns that your flat panel requires EXAMPLE If your flat panel uses M8 screws use the M8 mounting points Universal Washer Installation Pre installthemountingscrews spacersandwashers Oncemounted pushdowntoeliminatemovementfromthebr...

Страница 10: ...rface andidentifythethreadedmountingpointsthatarelocatedonthe back of the flat panel Step 2 Determine the correct screw length by carefully inserting a straw or toothpick and mark the depth of the mounting point Step 3 If your flat panel has a curved back or a recessed mounting point a universal spacer must be used Step 4 If needed place the universal spacer between the mounting bracket and the fl...

Страница 11: ...fullyonthe upper and lower mounting rails Fixed 5 Tilt Bracket Installation Optional The fixed tilt brackets allow for a fixed forward 5 tilt Please read the following installation instructions to attach the fixed tilt brackets Mounting Bracket M6 x 8mm Screw M4 x 6mm Screws Step 1 Pre install two 2 M4 x 6mm screws to the fixed tilt bracket Step 2 Slide the tilt bracket through the openslotsoftheu...

Страница 12: ...Step 1 Slide the security bar between the lower mounting rail and the bottom of the wall plate Flat Panel Wall Plate Mounting Bracket Security Bar Security Safety Bar Installation The safety bar may be mounted from either side of the flat panel Donotreleasetheflatpaneluntilthetopandbottomhooksofthe arms are resting fully on the upper and lower mounting rails ...

Страница 13: ...PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt fro...