background image

VZ-WM60

Page 2 

Visit the ViewZ website at http://www.viewzusa.com

 

Installation Instructions

Contact ViewZ with any questions: 

(888) 99-ViewZ

techsupport@viewzusa.com

Contents

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND 

 

COMPLETELY UNDERSTOOD. THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND 
PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REF-
ERENCE.
VIEWZ DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY VIEWZ PRODUCT FOR PUR-
POSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED 

 

ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, 

 

ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER 

 

RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, THE 

 

MOUNTING STRUCTURE MUST BE REINFORCED. THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT 

 

IS 130LBS. PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE 

 

INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL 

 

INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY 
GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

At least two qualified people should perform the assembly procedure. Injury and/or damage can result from dropping or mishandling the  
flat panel.

If mounting to studs, make sure that the mounting screws are anchored into the center of the studs. Use of an edge-to-edge stud finder is  
recommended.

Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are no electrical wires 
in wall. Cutting/drilling into an electrical line may cause serious injury.

Make sure there are no water lines inside the wall where the mount is to be located. Cutting/drilling into a water line may cause severe water 
damage to the mounting surface.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.

Warning Statements

Weight Limit

Maximum Flat Panel Weight: 

175 lbs.

THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 

AT LEAST FIVE TIMES THE WEIGHT OF THE FLAT PANEL. IF 

NOT, THE WALL STRUCTURE MUST BE REINFORCED. 

Weight Limit. ............................................................................................................................................................. 2

Warning Statements. ................................................................................................................................................ 2

Installation Tools. ...................................................................................................................................................... 3

Parts List................................................................................................................................................................... 3

Mounting Hardware. ................................................................................................................................................. 4

Nylon Spacers and Flat Washers. ............................................................................................................................ 4

Features. .................................................................................................................................................................. 5

Wood Stud Installation. ............................................................................................................................................. 6

Concrete Surface Installation. .................................................................................................................................. 7

Universal Spacer Installation. ................................................................................................................................... 9

Universal Washer Installation. .................................................................................................................................. 9

Mounting Bracket Installation. ................................................................................................................................ 10

Fixed Tilt Bracket Installation (Optional). ................................................................................................................ 10

Attaching the Flat Panel to the Wall Plate. ............................................................................................................. 11

Technical Specifications.

 ........................................................................................................................................ 12

Warranty. ................................................................................................................................................................ 13

Disclaimer ............................................................................................................................................................... 13

Содержание VZ-WM60

Страница 1: ... AMERICA 177 W Orangethorpe Ave Placentia CA 92870 USA USA and Canada Phone 1 888 99 ViewZ Other Locations Phone 001 714 996 1177 Fax 001 714 996 1138 VZ WM60 Universal Low Profile Flat Mount for 40 to 55 ViewZ Monitors 853177002847 ...

Страница 2: ...SSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY At least two qualified people should perform the assembly procedure Injury and or damage can result from dropping or mishandling the flat panel If mounting to studs make sure that the mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is recommended Beawareofthemountingenvironment Ifdrillingand orcuttingintothem...

Страница 3: ...inning installation If there are parts missing and or damaged please stop the installation and contact ViewZ 888 99 ViewZ Installation Tools not supplied Wall Plate Qty 1 Security Bar Qty 1 Mounting Brackets Qty 2 Universal Washers Qty 6 5 16 x 3 Lag Bolts Qty 6 Flat Washers Qty 6 Universal Spacers Qty 24 Fixed Tilt Bracket Qty 2 Phillips Screwdriver 1 4 Drill Bit Electronic Stud Finder Drill Leve...

Страница 4: ... x 30mm Qty 6 M4 x 16mm Qty 6 M6 x 45mm Qty 6 M6 x 30mm Qty 6 M6 x 25mm Qty 6 M6 x 16mm Qty 6 M5 x 30mm Qty 6 M5 x 25mm Qty 6 M5 x 16mm Qty 6 M8 x 70mm Qty 4 M8 x 45mm Qty 6 M8 x 30mm Qty 6 M8 x 25mm Qty 6 M8 x 16mm Qty 6 If your unit requires alternative mounting hardware use commercially available hardware or contact ViewZ 888 99 ViewZ ...

Страница 5: ...exact center of your flat panel on the wall Low Profile Design Holds the flat panel less than 1 from the wall Cable Electrical Cut Out Large cut outs on the wall plate allow for easy cable access and power distribution Universal Spacers Uniquely designed spacers that fit multiple screw sizes Mounting Slots Allow for a variety of stud configurations and lateral shift adjustments when mounting your ...

Страница 6: ...n the desired viewing location and mark the center of the visual centering diamond Step 2 If the location is acceptable use a stud finder to determine the exact center of each stud Step 3 Once all of the studs have been located adjustthewallplatetomatchtheclosest location of the center diamond mark while hitting at least two found stud positionswiththemount Useapencilto mark these mounting locatio...

Страница 7: ...damage to property Step 1 Place the wall plate into position against the wall keeping it level Step 2 Mark off four holes to be used for securing the mount and place the wall plate aside Solid Surface Cinder Block Step 3 Next drill holes using an electric drill and masonry bit The drill bit size that is used will depend on the size of the hardware used Step 4 Insert a concrete anchor into each hol...

Страница 8: ...e and verify the depth of the remaining thread inserts Step 4 Locate the correct diameter screw for the thread insert Step 5 Compare your thread depth indicator marking to the screw length Figure 1 Figure 2 Figure 3 Inverted Flat Panel Display Marking the Depth Thread Insert Thread Depth Indicator Thread Depth Indicator Marking Screw Marking Screw Thread Depth Indicator When using the universal sp...

Страница 9: ...rsal spacer can fit M4 M5 M6 and M8 screws sizes You may not need to use any spacers for your particular flat panel The universal washer will fit M4 M5 M6 and M8 hole patterns that your flat panel requires EXAMPLE If your flat panel uses M8 screws use the M8 mounting points Universal Washer Installation Pre installthemountingscrews spacersandwashers Oncemounted pushdowntoeliminatemovementfromthebr...

Страница 10: ...rface andidentifythethreadedmountingpointsthatarelocatedonthe back of the flat panel Step 2 Determine the correct screw length by carefully inserting a straw or toothpick and mark the depth of the mounting point Step 3 If your flat panel has a curved back or a recessed mounting point a universal spacer must be used Step 4 If needed place the universal spacer between the mounting bracket and the fl...

Страница 11: ...fullyonthe upper and lower mounting rails Fixed 5 Tilt Bracket Installation Optional The fixed tilt brackets allow for a fixed forward 5 tilt Please read the following installation instructions to attach the fixed tilt brackets Mounting Bracket M6 x 8mm Screw M4 x 6mm Screws Step 1 Pre install two 2 M4 x 6mm screws to the fixed tilt bracket Step 2 Slide the tilt bracket through the openslotsoftheu...

Страница 12: ...Step 1 Slide the security bar between the lower mounting rail and the bottom of the wall plate Flat Panel Wall Plate Mounting Bracket Security Bar Security Safety Bar Installation The safety bar may be mounted from either side of the flat panel Donotreleasetheflatpaneluntilthetopandbottomhooksofthe arms are resting fully on the upper and lower mounting rails ...

Страница 13: ...PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt fro...