Other Information
41
ViewSonic
VT2755LED
ENGLISH
If the Command is Not valid, Command Type= “-”, Only for HDTV power status on
standby.
Name
Length
Command
Type
CR
Byte Count
1 Byte
1 Byte
1 Byte
Bytes order
1
2
3
Example1: Get power status on standby and this command is valid.
Send (Hex Format)
Name
Length
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x36
0x67
0x6C
0x30
0x30
0x30
0x0D
Reply (Hex Format)
Name
Length
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x36
0x72
0x6C
0x30
0x30
0x30
0x0D
Example2: Get Brightness from TV-05 and this command is valid.
The Brightness value is 67.
Send (Hex Format)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x35
0x67
0x62
0x30
0x30
0x30
0x0D
Reply (Hex Format)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x35
0x72
0x62
0x30
0x36
0x37
0x0D
Example3: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name
Length
ID
Command
Type
Command
Value1
Value2
Value3
CR
Hex
0x38
0x30
0x35
0x67
0xD3
0x30
0x30
0x30
0x0D
Reply (Hex Format)
Name
Length
ID
Command
Type
CR
Hex
0x34
0x30
0x35
0x2D
0x0D