background image

10

Manual Screw Valve DV-5005DFS /-L

7   Commissioning

After all preparations have been completed and all lines connected,
the valve must still be filled with material. Either a cartridge or a pressure tank with 
material line has been connected to the material inlet.

7.1  Fill spindle with material

1.  Turn on the air pressure to the barrel to 12 psi for solder paste or lower if using an  
  adhesive or an epoxy. Do not attach a dispense needle.
2.  Now turn on the motor and let it run until material consistently flows out the valve  
 outlet.
3.  Stop the motor and connect a dispensing needle.
4.  Switch the motor on again until material is continuously coming out of the 
  dispensing needle.

7.2  Changing the spindle

Removal: 
1.  Turn off material feed pressure
2.  Remove the material barrel.
3.  Loosen the locking screw and open the door.
4.  Turn the spindle body approx. 30° to the right and pull it downwards from the  
  motor shaft.

Installation of a new spindle:
1.  Insert new Disposable Path into the Valve Housing. Make sure the Square
  Drive of the Motor Shaft captures the Feed Screw Collar.
2.  Push the Material Inlet Port of the Disposable Path inside the Housing Grove.
3.  Close the Housing Door and tighten the Panel Screw.
4.  Refer to Paragraph 7.1 (fill spindle with material) to purge.

8   Troubleshooting

The following list of problems and solutions will improve your dispensing operation. 
Most problems can be traced to the dispense material, especially when encountering 
problems with solder paste dispensing.
*Excessive up and down or „Z“ motion acceleration and velocity can cause filled materi-
als to separate. Decreasing the Z-axis acceleration and velocity or decreasing the barrel 
size will help to prevent this.

VIEWEG

Содержание 504847

Страница 1: ...User manual Screw Valve DV 5005DFS L Dosier und Mischtechnik Version 2018 08 01...

Страница 2: ...hortest possible time With the exchangeable material spindle all these problems could be solved The precisely manufactured plastic spindle can be replaced quickly and easily Cleaning the valve is cons...

Страница 3: ...No V 0070 Reducing rings 10 cc Item No 560943V 5 cc Item No 561184V 3 cc Item No 561183V 30 cc conditioner in a syringe barrel Item No 990223 30 Dispensing tip set small Item No 990062 K Connecting ca...

Страница 4: ...t motor only 60 70 mA Starting current max 1 5 A Terminal resistance 21 6 Ohm Size 153 x 40 x 34 mm Weight 235 gr Output shaft speed 400 U min Maximum air pressure requirement 20 psi Wetted material p...

Страница 5: ...2 K 10 Panel screw V 0092 11 Door right V 0093 11 Door left V 0093 L 12 Elbow 90 deg Luer Lock 78 13 Luer Lock male Luer Lock 77 depending on version Tip cap V 0094 Connection socket Lemo V 0059 Squar...

Страница 6: ...erial flow from this point to the dispense tip 4 is controlled by the feed screw rotation in the feed direction The feed screw is driven by the motor Applying a DC voltage signal to the motor 5 will r...

Страница 7: ...g bracket or customer supplied bracket should be attached to the Z axis in a manner that will provide the valve perpendicular travel to the horizontal plane of the surface on which the fluid material...

Страница 8: ...ntrol option involves using the TS5100 valve controller The TS5100 provides a regulated current limited DC signal to a 6 0 watt version of the valve The footswitch activating circuit shown in Figure 5...

Страница 9: ...nd connect the spindle valve DV 5005DFS to the control unit VC 1100 6 3 Compressed air supply Cartridges in sizes 55 cc 30 cc 10 cc and 5 cc can be directly connected to the material inlet If larger c...

Страница 10: ...ove the material barrel 3 Loosen the locking screw and open the door 4 Turn the spindle body approx 30 to the right and pull it downwards from the motor shaft Installation of a new spindle 1 Insert ne...

Страница 11: ...trate Increase gap Tip bent or damaged Replace tip Excessive paste for size of needle Decrease motor run time Overfeeding the feed screw Decrease air pressure on barrel Paste has separated Replace wit...

Страница 12: ...VIEWEG GmbH Dosier und Mischtechnik Gewerbepark 13 85402 Kranzberg Deutschland Tel 49 8166 6784 0 Fax 49 8166 6784 20 info dosieren de www dosieren de VIEWEG...

Отзывы: