9
SC1010
Steuergerät VC1140
zum Motor
zum Fußschalter
DV-5005DFS
VC1100 Serie
Manual Screw Valve DV-5005DFS /-L
A normally open contact is required to trigger the VC1100 control unit. If your XYZ
system does not provide a normally open contact, but only a 24 V signal, an adapter box
can be used (order no. 990234-4100).
The box converts the 24 V signal into a signal that can be sent directly to the VC 1100
control unit.
If the connection between the XYZ system and VC 1100 is established, set the
Control unit VC 1100 „manual“ and connect the spindle valve DV-5005DFS to the control
unit VC 1100.
6.3 Compressed air supply
Cartridges in sizes 55 cc, 30 cc, 10 cc and 5 cc can be directly connected to the material
inlet. If larger cartridges are to be connected, this can be done via material lines such as
the 580047A series with Luer-Lock connection.
The filtered air supply must be regulated and should initially be set between 1 to 15 psi.
Important!
The air supply is not used as the dispensing force. It is only required to move material
to the feed screw chamber. The minimum pressure required to move the material is the
optimum air pressure!
Fig. 6
to foot switch
Valve controller VC 1140
to motor
XYZ - Dispensing Robot
24 V signal
Adapter box