Problem
Possible causes
What to do
F3/F4
Temperature sensor of the induction
coil failure
Please contact the supplier.
F9/FA
Temperature sensor of the IGBT
failure.
Please contact the supplier.
E1/E2
Abnormal supply voltage
Please inspect whether power
supply is normal.
Power on after the power supply is
normal.
E3
High temperature of the induction
coil temperature sensor
Please contact the supplier.
E5
High temperature of the IGBT tempera-
ture sensor
Please restart after the hob cools
down.
Heat settings
Failure display and inspection
If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes:
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and
damages to the induction hob.
Cooking Hob
Viesta I4Z
Viesta I3Z
Viesta I2Z
Cooking Zones
4 Zones
3 Zones
2 Zones
Supply Voltage
220-240V~ 50/60Hz 220-240V~ 50/60Hz 220-240V~ 50/60Hz
Installed Electric
Power
6600 - 7200W
5300 - 5800W
3300W - 3600W
Product Size
L×W×H(mm)
590×520×62
590×520×62
288×520×62.5
Building-in Dimen-
sions A×B (mm)
560×490
560×490
268×500
Technical specification