Solar System Design Guide
53
6020 457 - 01
Required Installation Area (Flat Roofs) - Vitosol 200-FM, Type SV
Vitosol 200-FM SV2F Array Dimensions
Flat Roof Installation
Collector Array Weight
(Collectors, racking, fittings & fluid)
Number of
Collectors
Mounting Frame Spacing
Dimensions
Overall Length of Array
When Collectors Installed
“X” = 23½ in (595 mm)
“Y” = 18
7
/
8
in (481 mm)
in.
(mm)
lb.
(
kg)
1
Collector
1x "X"
42
a
(1071)
142
(65)
2
Collectors
2x "X" + 1x "Y"
84
b
(2148)
278
(126)
3
Collectors
3x "X" + 2x "Y"
127
(3225)
414
(188)
4
Collectors
4x "X" + 3x "Y"
169
a
(4301)
549
(249)
5
Collectors
5x "X" + 4x "Y"
211
c
(5378)
685
(311)
6
Collectors
6x "X" + 5x "Y"
254
a
(6455)
820
(372)
7
Collectors
7x "X" + 6x "Y"
296
b
(7532)
958
(435)
8
Collectors
8x "X" + 7x "Y"
339
(8609)
1094
(496)
9
Collectors
9x "X" + 8x "Y"
381
a
(9685)
1229
(558)
10
Collectors
10x "X" + 9x "Y"
423
c
(10762)
1365
(619)
11
Collectors
11x "X" + 10x "Y"
466
(11839)
1500
(681)
12
Collectors
12x "X" + 11x "Y"
508
b
(12916)
1636
(742)
*
* Only one pair of mounting crossbars
are supplied for 1 to 6 collectors,
two pairs of mounting crossbars are
supplied for 7 to 10 collectors.
For vertical collectors installed between 25° - 60° degrees from the horizontal plane (ground)
Note:
It is recommended that a minimum service
clearance of 12 in. (305 mm) should be added
to each end of the collector array. This allows for
ease of installation and servicing of the solar supply
and return connections.
Design Information